Download Print this page

Dyson DC18 Service Manual page 38

Hide thumbs Also See for DC18:

Advertisement

service manual
161
Prise the pedal plunger and spring out of
the undercarriage assembly.
162
To refit, locate the spring onto the pedal
plunger. Locate the end of the spring onto the
retaining channel in the undercarriage. Press the
pedal plunger hinge points in to the retainers in
the undercarriage.
163
Once fitted position the undercarriage into
the upright position. Ensure the pedal plunger
slides into the channel shown.
35
164
After replacing the pedal or pedal plunger
test the undercarriage assembly for actuation.
165
To remove the lock arm, remove the screws
and plastic washers from either side of the
undercarriage assembly.
166
Firmly pull the hinge points out of the
undercarriage.