Sub assemblies - cleaner head -
assemble
115
Align the swivel catch spring with the locator
on the brushbar motor cover. Press the swivel catch
into place.
116
Slide the brushbar motor cover onto the
brush housing assembly. Refit and tighten the
two cheesehead screws.
117
Refit the gimble cover onto the front of the
brushbar motor cover. Refit and tighten the two
cheesehead screws.
27
118
Refit the motor mounts onto the ribs inside
the brushbar motor cover.
119
Locate the rear of the cleanerhead
connector block onto the shelf in the brushbar
motor cover. Press the front of the block into
the brushbar motor cover until the catch clips
into place.
120
Reconnect the white wire from the cleanerhead
connector block onto the PCB assembly.