Tickets With Gap - Intermec EasyCoder F2 Installation And Operation Manual

Bar code label printer
Hide thumbs Also See for EasyCoder F2:
Table of Contents

Advertisement

Paper, cont'd.

Tickets with Gap

Intermec EasyCoder F2 – Installation & Operation Ed. 1
a
Web Width:
Maximum .......................... :
Minimum (standard) .......... :
Minimum (Quick-Load) .... :
b
Copy Length:
Min. length between slots .. :
Max. length between slots .. : depends on DRAM memory size
Under favourable circumstances, a minimum ticket length down to
4 mm (0.16") could be used. It requires the sum of the copy length
(b) and the detection slit height (e) to be larger than 7 mm (0.28"),
that batch printing is used, and that no pull back of the paper is
performed. Intermec does not guarantee that such short labels will
work, but it is up to the user to test this in his unique application.
c
LSS Detection Position:
Five fixed positions (distance from inner edge of paper):
3 mm
(.118")
8 mm
(.315")
12 mm
(.472")
16 mm
(.639")
20 mm
(.787")
d
Detection Slit Length:
The length of the detection slit (excluding corner radii) must be
minimum 2.5 mm (0.10") on either side of the LSS detection posi-
tion (e).
e
Detection Slit Height:
Maximum .......................... :
Recommended ................... :
Minimum .......................... :
Media Type Setup:
• Ticket (w gaps)
Do not allow any perforation to break the edge of the web, as this
may cause the web to split, resulting in a paper jam.
Appendix 2
Media Specifications
60.0 mm
(2.36")
25.0 mm
(1.00")
40.0 mm
(1.57")
8.0 mm
(0.32")
21.3 mm
(0.83")
1.6 mm
(0.06")
1.2 mm
(0.05")
92