Hussmann ESC Installation And Operation Manual page 21

Deli/meat/fish service case
Table of Contents

Advertisement

Rev. 0303
6. VERTICAL AND FRONT TO BACK ADJUSTMENT
AND OPENING OVERLAP PROBLEMS
• V
A
ERTICAL
DJUSTMENT
1. Remove
2. Lift open
top glass
glass panel(s)
and panel
and relieve
enclosing
tension on
mini-top
hinge.
hardware.
• F
B
A
RONT–
ACK
DJUSTMENT
1. Remove
2. Estimate
top glass
amount of
and panel
adjustment
enclosing
and make
mini-top
pencil mark
hardware.
on the
NOTE: Standard shim thickness is 1/16"
3. Loosen hex screw
4. Add or remove
(1/4" allen).
shims as needed.
Remove chrome
(see note on shims
access plate in order
below)
to hold nut plate.
Inside
Chrome cap
of Case
for access to
nut plate
3. Lift open
4. Loosen hex screw
glass panel(s)
(1/4" allen) slightly.
and relieve
Remove chrome
tension on
access plate in order
hinge.
to hold nut plate.
5. Close glass panel(s)
and check alignment
Retighten hex screw
and reinstall removed
components.
nut
Back
plate
of Case
CUT VIEW:
Mini Top
Hardware
5. Slide the mini-top
forward or backward
to the mark in step 2.
Check alignment of
glass.
Retighten components.
21

Advertisement

Table of Contents
loading