Download Print this page
Hussmann ESBDS Technical Data Sheet
Hussmann ESBDS Technical Data Sheet

Hussmann ESBDS Technical Data Sheet

Hussmann impact elite esbds merchandisers: data sheet

Advertisement

G
C
(Optional
Lights)
We reserve the right to change or revise specifications
and product design in connection with any feature of
our products. Such changes do not entitle the buyer to
corresponding changes, improvements, additions or
replacements for equipment previously sold or shipped.
Item
Part #
Description
F
A
T
AN
SSEMBLIES AND
HERMOSTATS
A.
0392457
Fan Motor, Evaporator (120V)
(MO.4410101)
0409511
Fan Blade (120V) (FB.0409511)
embossing toward motor
0436517
Fan Motor, Evaporator (230V)
(MO.4410105)
0409512
Fan Blade (230V) (FB.0409512)
embossing toward motor
B.
0404551
Fan Motor, Ambient (120V)
(MO.0404551)
0404552
Fan Motor, Ambient (230V)
(MO.4410590)
C.
0382028
Standard Non-adjustable
Defrost Thermostat
(CT.0382028)
D.
0353949
Optional Adjustable
Refrigeration Thermostat
(CT.4481087)
Note: Changed items have been underlined.
©2007 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM
Thermostat Bulb
Location
B
E
G
Wiring Item #
Item
H
EATERS
E.
(1)
E.
L
AMPS AND
F.
F.
(2)
F.
F.
(3)
G.
(4)
Technical Data Sheet
P/N 0453556_B
NSF
D
F
A
Part #
Description
0460453
Heater, Ambient (120V)
(HE.4850579)
0461866
Heater, Ambient (230V)
(HE.4850646)
B
ALLASTS
0355716
Ballast, Electronic, 2 lamps
(120V) (BA.0355716)
0355398
Ballast, Electronic, 3 lamps
(120V) (BA.4480118)
0440215
Ballast, Electronic, 2 lamps
(230V 50-60 Hz) (BA.4481267) (7)
0428652
Ballast, Electronic, 3 lamps
(230V 50-60 Hz) (BA.4480897) (8)
0385104
Ballast Transformer
(230V 50-60 Hz, per ballast)
(TR.4481191)
Fluorescent Lamp
Replace with like fixtures
ESBDS
®
Certified
January 2007
Wiring Item #
(5)
(6)
(7)
(8)
(9)
P/N 0453556_B

Advertisement

loading

Summary of Contents for Hussmann ESBDS

  • Page 1 (CT.0382028) 0353949 Optional Adjustable Refrigeration Thermostat (CT.4481087) Note: Changed items have been underlined. ©2007 HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 • MEXICO 1-800-522-1900 • WWW.HUSSMANN.COM Thermostat Bulb Location Wiring Item # Item Part # EATERS...
  • Page 2: Plan Views

    Refrigeration Outlet Back of case to center of refrigeration outlet (E) RH end of case to center of refrigeration outlet 2 of 6 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Dimensions shown as in. and (mm). Electrical Refrigeration Waste Outlet...
  • Page 3 NSF Certification These merchandisers are manufactured to meet ANSI /National Sanitation ® Foundation (NSF ) Standard #7 requirements. P/N 0453556_B HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM Dimensions shown as in. and (mm). (210) (692) (787) COIL (629)
  • Page 4: Electrical Data

    115V Lighting Circuit Total = Standard Lighting + Total Optional Lighting + Optional Shelf Lighting 230V Lighting Circuit Total = Multiply 115V Lighting Circuit Total by 4 of 6 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. 4 ft 6 ft 8 ft...
  • Page 5 G = Green BL = Blue LB = Light Blue DB = Dark Blue B = Black W = White = 120V P OWER P/N 0453556_B HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A. • WWW.HUSSMANN.COM 120V NEUTRAL ROWN Fans Defrost...
  • Page 6 Light Circuits All components must have mechanical ground, and the merchandiser must be grounded. R = Red = 120V P OWER 6 of 6 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Standard Lighting 2 Row Canopy RANGE OR connectors connectors connectors...

This manual is also suitable for:

Impact elite esbds