Electrical; Wiring Color Code; Ashrae Color Code - Hussmann ESC Installation And Operation Manual

Deli/meat/fish service case
Table of Contents

Advertisement

Rev. 0303

WIRING COLOR CODE

S TA N DA R D C A S E W I R E C O L O R C O D E
GREEN
PURPLE
ORANGE
YELLOW
RED
BROWN
BLACK/WHITE
BROWN
GRAY
FACT. INSTALLED T-STAT & SOLENOID
CASE MUST BE GROUNDED
NOTE: Refer to label affixed to case to determine the actual
configuration as checked in the "TYPE INSTALLED" boxes.
ELECTRICAL CIRCUIT IDENTIFICATION
Standard lighting for all models will be full length fluores-
cent lamps located within the case at the top.
The switch controlling the lights, the plug provided for
digital scale, and the thermometer are located at the rear
of the case mullion.
The receptacle that is provided on the exterior back of
these models is intended for computerized scales with a
five amp maximum load, not for large motors or other
high wattage appliances. It should be wired to a dedicated
circuit.
ELECTRICAL SERVICE RECEPTACLES
(WHEN APPLICABLE)
The receptacles located on the exterior of the merchan-
diser are intended for scales and lighted displays. They
are not intended nor suitable for large motors or other
external appliances.
BEFORE SERVICING
ALWAYS DISCONNECT ELECTRICAL
POWER AT THE MAIN DISCONNECT
WHEN SERVICING OR REPLACING ANY
ELECTRICAL COMPONENT.
This includes (but not limited to) Fans, Heat-
ers, Thermostats, and Lights.
GROUND
ANTI-SWEAT
LIGHTS
RECEPTACLE
T-STAT 230V
FAN MOTORS
T-STAT 115V
FAN MOTORS/T-STAT 115 V
SOL-VALVE

Electrical

FIELD WIRING & SERIAL PLATE AMPERAGE
Field Wiring must be sized for component amperes
printed on the serial plate. Actual ampere draw may be
less than specified. Field wiring from the refrigeration
control panel to the merchandisers is required for re-
frigeration thermostats. Most component amperes are
listed in the "Case Specs" section, but always check the
serial plate.
BALLAST LOCATION
Ballasts are located within the access panel that runs
the length of the rear of the case. Refer to T-stat loca-
tion in previous section. They are located in the same
area.

ASHRAE COLOR CODE

NOTE: All other manufacturers; no known sensor codes
SENSOR COLORS
Case Control Systems
Manufacturer ® >
Location
Coil Inlet
Color
Part#
Coil Outlet
Color
Part#
Discharge Air
Color
Part#
Return Air
Color
Part#
Defrost Term.
Color
Part#
Color
Liquid Line
Part#
13
EIL
CPC
Blue
Blue
225-01-1755225-01-3255
Red
Red
225-01-1757225-01-3123
Green
Green
225-01-1756225-01-3260
Purple
Green
225-01-1758225-01-3260
White
Orange
225-01-0650225-01-3254
White
Blue
225-01-0650225-01-3255

Advertisement