replacements for equipment previously sold or shipped.
Item
Part #
Description
F
A
T
AN
SSEMBLIES AND
HERMOSTATS
A.
0404551
Fan Motor, Ambient (120V)
0404552
Fan Motor, Ambient (230V)
B.
0353949
Optional Adjustable
Refrigeration Thermostat
Note: Changed items have been underlined.
HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A.
Thermostat Bulb
Location
A
Wiring Item #
Item
L
AMPS AND
(1)
C.
C.
(2)
C.
C.
D.
P/N 0453555A
NSF
B
Part #
Description
B
ALLASTS
0355716
Ballast, Electronic, 2 lamps
(120V)
0355398
Ballast, Electronic, 3 lamps
(120V)
0440215
Ballast, Electronic, 2 lamps
(230V 50-60 Hz)
0428652
Ballast, Electronic, 3 lamps
(230V 50-60 Hz)
0385104
Ballast Transformer
(230V 50-60 Hz, per ballast)
Fluorescent Lamp
Replace with like fixtures
ESGMS
Data Sheet Set
®
Certified
October 2005
C
Wiring Item #
(3)
(4)
(3)
(4)
(5)
P/N 0453555A

Advertisement

loading

Summary of Contents for Hussmann ESGMS

  • Page 1 0404551 Fan Motor, Ambient (120V) 0404552 Fan Motor, Ambient (230V) 0353949 Optional Adjustable Refrigeration Thermostat Note: Changed items have been underlined. HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Thermostat Bulb Location Wiring Item # Item Part # AMPS AND ALLASTS 0355716...
  • Page 2: Plan Views

    Refrigeration Outlet Back of case to center of refrigeration outlet (E) RH end of case to center of refrigeration outlet 2 of 6 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Dimensions shown as in. and (mm). Electrical Refrigeration Waste Outlet...
  • Page 3 Electrical (422) (318) (508) (102) (667) (845) HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. ESGMS Impact Elite Meat / Delicatessen REFRIGERATION DATA Note: This data is based on store temperature and humidity that does not exceed 75°F and 55% R.H. Schedule defrost at night while lights are off.
  • Page 4: Electrical Data

    Standard Lighting* (120V 60hz) 2 Row Canopy Optional Lighting 1 Row Ledge 1 Row Rail *230V lighting values are under review. 4 of 6 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. 4 ft 6 ft 8 ft 12 ft Amperes 4 ft...
  • Page 5 = 120V P OWER P/N 0453555A 120V NEUTRAL ROWN Fans WARNING = 120V N = Field G EUTRAL HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. Ambient Fan Wiring Glass Air Wipe Offtime Defrost Refrigeration Thermostat (Field Installed) Light Blue Condensing Unit...
  • Page 6: Light Circuits

    All components must have mechanical ground, and the merchandiser must be grounded. R = Red = 120V P OWER 6 of 6 HUSSMANN CORPORATION, Bridgeton, MO 63044-2483 U.S.A. RANGE OR WARNING Circled Numbers = Parts List Item Numbers Grayed components in 12 foot models only.