P/N 0467434_D

SHIPPING RIDER

Each case is shipped on a rider to protect the factory
installed legs, and to make positioning the case easi-
er. DO NOT remove the rider until the case has
been positioned. Once the rider is removed, the
case must be lifted –NOT PUSHED– to reposition.
To remove the rider, remove bolts attaching rider
to each leg.
Remove Bolts from Front

CASE LEVELING

Merchandisers must be installed level to ensure
proper operation of the refrigeration system and
to ensure proper drainage of defrost water.
During all steps of setting, joining and leveling
cases, close attention to position and operation
must be maintained.
NOTE: B
EGIN LINEUP LEVELING FROM THE HIGHEST
POINT OF THE STORE FLOOR
Preparation
1. Using store blueprints, measure off and mark
on floor the exact dimensions/locations of the
case footprint. A 3 inch space is required
behind each wall case to prevent condensation.
2. Snap a chalk line for the front and rear
positions of the base legs.
3. Mark the location of each joint from front to
back lines.
HUSSMANN CORPORATION • BRIDGETON, MO 63044-2483 U.S.A.
.
4. FLOORS ARE NOT LEVEL!!! When
working with two or more cases to be joined, the
whole lineup must be leveled on the same plane,
left to right and front to back. This means that the
entire lineup must be brought up to the level of
the highest case in the lineup.
Along the lines previously marked, find the
highest point of the floor by:
• Walking the floor and noticing any dips or
mounds;
• Using a string level or laser level; and
• Using a transit.
Leveling
Position the first case at the highest point on the
floor. Work outward from that point to create the
case line-up. Use a 48 inch (1220 mm) or longer
level for end-to-end leveling. The discharge
nosing of the case is a good location for the level
at the rear of the case (center of wide island), and
the handrail or return nosing is a good location
for the level at the front of the case. For leveling
the case front-to-rear, a 24 inch (610 mm) level
should be placed on the flange of the case end
frame. Suggested level locations are shown in the
following illustrations.