I
1-14
NSTALLATION
INSTALLING PARTITIONS
To join same temperature fixtures on different
defrost cycles, an acrylic partition kit is
required.
To join unlike fixtures, or like fixtures operating
at different temperatures, an insulated partition
kit is required. It must be installed when setting
the lineup.
Instructions for installing these partitions are
included with the kits.
P/N 0467434_D
INSTALLING END ASSEMBLIES
End assemblies are normally factory installed.
The following information is provided for
retrofit or field installation.
1. Prepare Case
a. Remove display racks, pans, front rack
supports and front air grilles from section of
case where end is to be installed.
b. Remove the interior back panel. No tools
required.
2. Apply gaskets to end frame as shown on
pages 1-5 and 1-6.
3. Fasten End Assembly to Merchandiser
a.
Use Bolt and washer to fasten end
assembly to merchandiser in the same way
the end case is fastened.
b.
Tighten in order shown for joining.
.
.
WWW
HUSSMANN
COM