5-4
Figure 5.2
Installing the iBBU Daughtercard on the ServeRAID-
MR10M Controller
J1
4. Carefully press the iBBU onto the controller, so that the two
connectors are firmly joined.
5. Secure the iBBU to the controller with the screws and the standoffs
in the three screwholes.
The standoffs are threaded at both ends and a screw goes into each
end.
6. Use the Phillips-head screws that are provided to secure the iBBU
to the controller.
Attention:
Center the screwdriver carefully to avoid stripping the
screwhead. Do not over-tighten the screws.
7. Install the controller in the computer in the PCI Express slot, as
shown in
Figure
Press down gently, but firmly, to make sure that the controller is
properly seated in the slot. The bottom edge of the controller must
be flush with the slot.
Attention:
Never apply pressure to the iBBU when you insert the
controller. Instead, press down only on the top edge of the
controller, as shown in
Installing the Intelligent Battery Backup Unit
5.3.
Figure
85021-03
5.3.