Table 6.5
Display Current BBU Properties (Cont.)
Description
Displays current properties of the BBU. The information displays in the following
formats:
BBU Properties for Adapter: x
Auto Learn Period: xxx Sec
Next Learn Time: xxxx Sec
Learn Delay Interval: xx Hours
Auto-Learn Mode: Warn via Event/Disabled/Enabled
6.1.2.6

Start BBU Learning Cycle

Table 6.6

Start BBU Learning Cycle

Convention
MegaCli -AdpBbuCmd -BbuLearn -aN|-a0,1,2|-aALL
Description
Starts the learning cycle on the BBU. No parameter is needed for this option.
6.1.2.7

Place Battery in Low-Power Storage Mode

Table 6.7

Place Battery in Low-Power Storage Mode

Convention
MegaCli -AdpBbuCmd -BbuMfgSleep -aN|-a0,1,2|-aALL
Description
Places the battery in Low-Power Storage mode. The battery automatically exits this
state after 5 seconds.
6.1.2.8

Set BBU Properties

Table 6.8

Set BBU Properties

Convention
MegaCli -AdpBbuCmd -SetBbuProperties -f<fileName> -aN|-a0,1,2|-aALL
Use the command in
selected controller(s). A learning cycle is a battery calibration operation
performed by the controller periodically (approximately every three
months) to determine the condition of the battery.
Use the command in
Storage mode on the selected controller(s). This saves battery power
consumption.
Use the command in
controller(s) after reading from the file.
Monitoring the IBBU with the MegaRAID Configuration Utilities
Table 6.6
to start the BBU learning cycle on the
Table 6.7
to place the battery into Low-Power
Table 6.8
to set the BBU properties on the selected
6-9