Removing The Serveraid-8K Or Serveraid-8K-L Sas Controller - IBM System x3755 Problem Determination And Service Manual

Hide thumbs Also See for System x3755:
Table of Contents

Advertisement

2. Carefully grasp the Remote Supervisor Adapter II SlimLine assembly by its top
3. Press the assembly firmly into the connector and under the retention latch on
4. Install the top cover (see "Replacing the top cover" on page 42).
5. Connect the cables and power cords (see "Connecting the cables" on page 40
6. Turn on all attached devices and the server.

Removing the ServeRAID-8k or ServeRAID-8k-l SAS controller

To remove the ServeRAID-8k or ServeRAID-8k-l SAS controller, complete the
following steps.
Connector
Interposer card
Mounting hole
Standoffs
a. Insert the standoffs that come with the option into the mounting holes in the
Remote Supervisor Adapter II SlimLine.
b. Align the mounting holes in the Interposer card with the standoffs; then,
align the connector on the card with the connector on the Remote
Supervisor Adapter II SlimLine.
c. Press the Interposer card and Remote Supervisor Adapter II SlimLine
together until fastened.
edge or upper corners, and align it with the guide and the connector on the I/O
board.
Attention:
Incomplete insertion might cause damage to the server or the
adapter.
the guide.
for cabling instructions).
Standoffs
Standoffs
Remote Supervisor
Adapter II SlimLine
Mounting hole
Chapter 4. Removing and replacing server components
59

Advertisement

Table of Contents
loading

This manual is also suitable for:

88777163

Table of Contents