8.1 Cooling Mode Operation

TOP PREVIOUS NEXT
Cooling in operation according to Remote Control setting.
When the compressor is stopped by Remote Control, it restarts after 3 minutes when the
Remote Control is turned ON.
When the setting temperature is reached during cooling operation, the compressor stops and it
will not start for 3 minutes.
The compressor will start automatically if it has stopped for 7 minutes even if the room
temperature is between the compressor ON temperature and OFF temperature.
If the temperature of the indoor heat exchanger falls continuously below 2°C for 4 minutes or
more, the compressor turns off to protect the indoor heat exchanger from freezing. The fan
speed setting remains the same.
Compressor will restart again when the indoor heat exchanger temperature rises to 10°C
(Recovery).
If the compressor is operating continuously for 5 minutes or longer and the temperature
Time Delay Safety Control (3 minutes)
7 minutes Time Save Control
Anti-Freezing Control
3 minutes waiting of Time Delay Safety Control is valid for Cooling Operation.
Compressor Reverse Rotation Protection Control