difference between intake air and indoor heat exchanger is 2.5°C or less for 2 minutes,
compressor will stop and restart automatically.
(TimeDelay Safety Control is valid)
▴ T = Intake air temperature - Indoor heat exchanger temperature
This is to protect reverse rotation of the compressor when there is a instantaneous power failure.
Purpose is to prevent dew formation on indoor unit air discharge area.
When the following conditions occur for 30 minutes continuously, anti-dew formation is
controlled by indoor fan speed shift to low (Changed to Lo+ ):
Indoor intake air temperature is more than 24°C and less than 30°C.
Remote Control setting temperature is less than 25°C.
Compressor is on.
Cooling operation mode.
Indoor Fan motor operate at Low fan speed.
This control is cancelled immediately when above condition is changed.
When Automatic Fan Speed is selected at Remote Control during cooling operation.
Fan speed rotates in the range of Hi to Me.
Deodorizing Control.
Anti-Dew Formation Control
Automatic Fan Speed Mode