12.2 Cross Flow Fan Indoor and Fan
Motor Removal Procedures
TOP PREVIOUS NEXT
1. In order to remove the Cross Flow Fan and Indoor Fan Motor, Control Board need to be taken
out by releasing all the connectors as indicated below.
A. Release the Earth Wire screw. (
B. Release the Intake Air Sensor. (
C. Release the Piping Sensor. (
D. Release the CN-REC/DISP connectors. (
E. Release the CN-STM1 connector. (
2. Pull out the Drain Hose from outlet to remove the Discharge Grille. (
3. Removing the right and left screws. (
4. By pressing down the hook at the left and pushing up the hook at the right, you will be able to
remove the Control Board. (
5. Remove the screw at the Cross Flow Fan. (
Fig. 5
)