8.2 Soft Dry Mode Operation
TOP PREVIOUS NEXT
The unit starts cooling operation until the room temperature reaches the setting temperature set
●
on the Remote Control, and then Soft Dry operation will start.
During Soft Dry operation, the Indoor Fan will operate at SLo speed.
●
Once room temperature reaches below Soft Dry OFF temperature. Indoor Fan, Compressor and
●
Outdoor Fan stop for 6 minutes.
Once the compressor stops, it will not start for 3 minutes during Cooling operation.
●
Same as Anti-Freezing Control for Cooling Mode operation. (For Soft Dry region, 6 minutes
●
waiting is valid during compressor stops.)
Same as Compressor Reverse Rotation Protection Control for Cooling Mode Operation. (For
●
Soft Dry region, 6 minutes waiting is valid during compressor stops.)
Same as Anti-Dew Formation Control for Cooling Mode operation.
●
When Automatic Fan Speed is selected at Remote Control during Soft Dry operation.
Fan speed off and on at SLo speed.
●
Deodorizing Control.
●
Time Delay Safety Control
Anti-Freezing Control
Compressor Reverse Rotation Protection Control
Anti-Dew Formation Control
Automatic Fan Speed Mode