Codes and Error Messages: Dell PowerVault 735N Systems Service Manual
correction
code(ECC) on
disk read
Controller has
failed
CD-ROM drive
not found
CPUs with
different level
2 cache sizes
detected
Data error
Decreasing
available
memory
Diskette drive
0 seek failure
Diskette drive
1 seek failure
Diskette read
failure
Diskette
subsystem reset
failed
Diskette write
protected
Drive not ready
Embedded server
management
error
Embedded server
management is
not present
Gate A20
failure
General failure
file:///C:/Users/Phebega_Pericho/Desktop/spv735N/en/sm/beep.htm[3/15/2013 4:18:15 PM]
subsystem or hard-disk drive
subsystem (defective system
board)
Improperly connected or
missing CD-ROM drive
Two different types of
microprocessors are installed
Faulty diskette, diskette drive,
or hard-disk drive
One or more DIMMs
improperly seated or faulty
Faulty or improperly inserted
diskette, incorrect
configuration settings in
System Setup program, loose
diskette/tape drive interface
cable, or loose power cable
Faulty diskette, faulty or
improperly connected
diskette/tape drive interface
cable, or loose power cable
Faulty diskette/tape drive
controller (defective system
board)
Diskette write-protect feature
activated
Diskette missing from or
improperly inserted in diskette
drive
Embedded server
management memory may be
temporarily corrupted
Faulty keyboard controller
(defective system board)
Operating system corrupted or
not installed properly
Check that the diskette drive/CD-ROM drive unit
is seated properly against the interposer board on
the peripheral cage. See "Drives."
Install a correct version of the
both microprocessors have the same level 2
cache size.
Replace the diskette, diskette drive, or hard-disk
drive.
Remove and reseat the
persists,
replace the
DIMMs.
Check that the diskette drive/CD-ROM drive unit
is properly against the interposer board on the
peripheral cage. Run the System Setup program
to correct the diskette drive type. See
System Setup
Program." Check the drive
interface and power cables.
Check that the diskette drive/CD-ROM drive unit
is properly against the interposer board on the
peripheral cage. See "Drives." Replace the
diskette-drive interface cable.
Replace the system
board.
Move the write-protect tab on the diskette.
Reinsert or replace the diskette.
Shut down the system to clear the memory, and
then restart the system.
Replace the system
board.
Reinstall the operating system.
microprocessor
DIMMs. If the problem
"Using the
so