Note: Stroke
Adjustment pin set
flush to pulling head
Clutch Tab
Position
WORKLIGHT FUNCTION
Refer to section 3.5 Worklight for function check
STROKE ADJUSTMENT SETTING, COLLET & NOSE HOUSING INSTALLATION
Refer to section 3.2 Nose Equipment and 3.3 Stroke Setting and Adjustment
OPERATION CHECK (Fig. 4)
Set 5-10 Neobolts and check for the following:
The tool does not slip
Swaging setting is done in one stroke
There is no pin tail damage on placed Neobolt
There is no abnormal noise
APPEARANCE CHECK
Inspect the tool for the folllowing:
Damage to the Handles (G) or Gear Housing Assembly (E)
Loose components and screws
Any oil spots on the housings
Peeling of the over mold (Rubber grip)
Blockage of Exhaust Vents (F)
Illegible or missing warning labels

5.3 SPARE PARTS AND TOOLS

For spare parts refer to "Bill of Material" in section 9
5.3.1 Tools required for maintenance:
21mm open end wrench, 1ea (Mast Housing)
2mm allen wrench, 1ea (Stroke Adjustment Pin)
24mm open end wrenches, 2ea (Anvil and Nose Housing)