Majestic Quartz Series Installation Manual page 27

Hide thumbs Also See for Quartz Series:
Table of Contents

Advertisement

Top Vent - Vertical Termination - (continued)
Three Elbows
Note: Use SLP Series
components only.
Note: There MUST be a 25%
reduction in total H when
using flex vent except when
using the simple up and out
installation. See Figure 4.8.
Figure 4.18
Majestic • QUARTZPLA36IN / QUARTZPLA36IL Installation Manual • 2643-980 Rev. B • 7/22
1/2 ft..
1-1/2 ft.
2-1/2 ft.
3-1/2 ft.
4-1/2 ft.
V
2
H
2
INSTALLED
HORIZONTALLY
V
H
+ H
Maximum
1
1
2
90º Elbow
0
152 mm
1 ft.
457 mm
2 ft.
762 mm
4 ft.
1.1 m
6 ft.
1.4 m
14 ft.
H
Maximum = 14 ft. (4.3 m)
1
*No specific restrictions on this value EXCEPT V
CANNOT exceed 40 ft. (12.2 m).
H
1
ALL MODELS
V
2
0
1-1/2 ft. 457 mm 1-1/2 ft. 457 mm
305 mm
*
*
610 mm
*
*
1.2 m
*
*
1.8 m
*
*
4.3 m
*
*
+ V
1
V
1
V
+ V
Minimum
1
2
*
*
*
*
*
*
*
*
*
*
+ H
+ H
2
1
2
27