Combustible Mantel Legs or Wall Projections
Combustible mantel and wall projections may be applied
over the non-combustible board supplied with the fire-
place when following the combustible projection figures
below.
Combustible Mantel Legs or Wall Projections
TOP VIEW
FIREPLACE OPENING
See Dimension B on Appliance
Dimension Diagram (Figure 3.1).
Figure 10.4 Combustible Mantel Leg or Wall Projection
(Acceptable on both sides of opening)
TOP VIEW
FIREPLACE OPENING
See Dimension B on Appliance
Dimension Diagram (Figure 3.1).
Figure 10.5 Combustible Mantel Legs or Wall Projections
(Acceptable on one side of opening)
Majestic • QUARTZPLA36IN / QUARTZPLA36IL Installation Manual • 2643-980 Rev. B • 7/22
58
Note: Clearance from opening
to perpendicular wall.
1/2 IN.
MINIMUM
2-7/8 IN.
MINIMUM
3 FT. MAXIMUM
Note: Clearance from opening
to perpendicular wall.
3 IN.
MINIMUM
5-7/8 IN.
MINIMUM
UNLIMITED
Non-Combustible Mantel Legs or Wall Projections
TOP VIEW
FIREPLACE OPENING
See Dimension B on Appliance
Dimension Diagram (Figure 3.1).
Figure 10.6 Non-Combustible Mantel Legs or Wall Projections
(Acceptable on both sides of opening)
Note: Clearance from opening
to perpendicular wall.
6 IN MAX.
UNLIMITED
3 IN. MIN.