Use Of Flex Vent (Slp-Flex Series 6-5/8 Inch) - Majestic Quartz Series Installation Manual

Hide thumbs Also See for Quartz Series:
Table of Contents

Advertisement

E. Use of Flex Vent (SLP-FLEX Series 6-5/8
Inch)
The flex vent must be supported with the spacing between
support intervals not exceeding 4 feet, with no more than
1/2 inch sag between supports.
A support is required at each change in venting direction,
and in any location where it is necessary to maintain the
necessary clearance to combustibles. A simple "up and
out" installation (Figure 4.8) requires only enough support
to maintain the necessary clearance to combustibles.
However, the vent attachment point and the firestop loca-
tion are considered to be supports.
TERMINATION
CAP
3 in. CLEARANCE
FLEX-VENT
1 in.
CLEARANCE
Figure 4.8 Flex Vent Pipe - Generic Fireplace Shown
Majestic • QUARTZPLA36IN / QUARTZPLA36IL Installation Manual • 2643-980 Rev. B • 7/22
20

Advertisement

Table of Contents
loading

This manual is also suitable for:

Quartz platinum 36Quartzpla36inQuartzpla36il

Table of Contents