Majestic 360DVS2 Installation Instructions & Homeowner's Manual

Multisided top/rear vent convertible direct vent majestic products, 360dvs series
Table of Contents

Advertisement

INSTALLER/CONSUMER
SAFETY INFORMATION
PLEASE READ THIS MANUAL
BEFORE INSTALLING
AND USING APPLIANCE.
IMPORTANT: Read all
instructions and warnings
carefully before starting
installation. Failure to follow
these instructions may result
in a possible fire hazard, and
will void the warranty.
WARNING: If the information in
this manual is not followed
exactly, a fire or explosion may
result, causing property damage,
personal injury, or loss of life.
FOR YOUR SAFETY:
• Installation and service must
be performed by a qualified
installer, service agency, or
the gas supplier.
• Do not store or use gasoline
or other flammable vapors
and liquids in the vicinity
of this or any other appliance.
If you smell gas:
1. Open windows
2. Do not touch electrical
switches.
3. Do not try to light any
appliance.
4. Extinguish any open flame.
5. Do not use any telephone in
your building.
6. Immediately call your gas
supplier from a neighbor's
phone.
7. Follow your gas supplier's
instructions.
8. If you cannot reach your gas
supplier, call the fire
department.
INSTALLER: DO NOT DISCARD THIS MANUAL—LEAVE FOR HOMEOWNER
Multisided Top/Rear Vent
Convertible Direct Vent
Fireplaces:
Installation Instructions &
Homeowner's
Vermont Castings, Majestic Products
410 Admiral Boulevard • Mississauga • Ontario, Canada L5T2N6 • Ph: 905-670-7777
www.majesticproducts.com • www.vermontcastings.com
360DVS2
360DVS3
360DVSL
360DVSR
Manual
10002547 09/03 Rev.8

Advertisement

Table of Contents
loading

Summary of Contents for Majestic 360DVS2

  • Page 1: Installation Instructions

    7. Follow your gas supplier's instructions. 8. If you cannot reach your gas supplier, call the fire Vermont Castings, Majestic Products department. 410 Admiral Boulevard • Mississauga • Ontario, Canada L5T2N6 • Ph: 905-670-7777 www.majesticproducts.com • www.vermontcastings.com INSTALLER: DO NOT DISCARD THIS MANUAL—LEAVE FOR HOMEOWNER...
  • Page 2: Table Of Contents

    Vermont Castings, Majestic Products, 360DVS Series Table of Contents Thank you, and Congratulations on your purchase of a Vermont Castings, Majestic Products Fireplace. PLEASE READ THE INSTALLATION & OPERATING INSTRUCTIONS BEFORE USING APPLIANCE. IMPORTANT: Read all instructions and warnings carefully before starting installation. Failure to follow these instructions fully may result in a possible fire hazard and will void the warranty.
  • Page 3: Notes For Safe Installation And Operation

    A professional service person should be It is not unusual for your Vermont Castings, Majestic contacted to inspect this fireplace annually. Make it a Products gas fireplace to give off some odor the first time it practice to have all of your gas fireplaces checked is burned.
  • Page 4: Fireplace Dimensions

    Vermont Castings, Majestic Products, 360DVS Series Fireplace Dimensions - 360DVS2 Rear Vent Configuration Electrical Electrical Access Access Gas Line Gas Line Access Access DVS2_dims_RV Top Vent Configuration Electrical Electrical Access Access Gas Line Gas Line Access Access DVS2_dims_TV Fig. 2a Fireplace specifications—360DVS2 Appliance Dimensions Ref.
  • Page 5 Vermont Castings, Majestic Products, 360DVS Series Fireplace Dimensions - 360DVS3/ 360DVSL/ 360DVSR Rear Vent Configuration Electrical Access Gas Line Access DVS3_dims_RV Top Vent Configuration Electrical Access Gas Line Access DVS3_dims_TV Fig. 2b Fireplace specifications—360DVS3/ 360DDVSL/ 360DVSR Appliance Dimensions Ref. Rear Vent Configuration Top Vent Configuration ”...
  • Page 6: Framing Dimensions

    Vermont Castings, Majestic Products, 360DVS Series Framing Dimensions - 360DVS2 Rear Vent Configuration CFM121 Top Vent Configuration CFM122 Fig. 3a Fireplace framing dimensions—360DVS2 Framing Dimensions Ref. Rear Vent Configuration Top Vent Configuration 24” minus two times finishing material thickness to be even with face of unit.
  • Page 7 Vermont Castings, Majestic Products, 360DVS Series Framing Dimensions - 360DVS3/ 360DVSL/ 360DVSR Rear Vent Configuration 360DVSR 360DVSL 360DVS/3/L/R 360DVS3 CFM123 Top Vent Configuration 360DVSR 360DVSL 360DVS/3/L/R 360DVS3 CFM124 Fig. 3b Fireplace framing dimensions—360DVS3/ 360DVSL/ 360DVSR Framing Dimensions Ref. Rear Vent Configuration Top Vent Configuration...
  • Page 8: Clearance To Combustibles

    Vermont Castings, Majestic Products, 360DVS Series Clearance to Combustibles Top View Appliance 0” (0 mm) to standoff Bottom 0” (0 mm) Vent End ” (13 mm) to rear panel Nonvent End (DVS2) 0” (0 mm) Venting Concentric sections of DV Vent: Top, bottom &...
  • Page 9: Framing & Finishing

    Vermont Castings, Majestic Products, 360DVS Series Framing & Finishing Input ratings are shown in BTU per hour and are certified without deration for elevations up to 1. Choose the unit location. 4,500 feet (1,370 m) above sea level. 2. Place the unit into position and secure it to the floor For elevations above 4,500 feet (1,370 m) in USA, with 1.5”...
  • Page 10: Electrical Junction Box Connection

    Vermont Castings, Majestic Products, 360DVS Series The gas control is equipped with a captured-screw type Electrical pressure test point, therefore it is not necessary to Inlet Hole provide a " test point upstream of the control. When using copper or flex connector, use only approved fittings.
  • Page 11: Optional Top Vent Application

    Vermont Castings, Majestic Products, 360DVS Series Remove these screw Remove these screws On/Off_switch_loc Outer collar Fig. 8 Alternate switch location adapter Fig. 7 Fig. 9 Remove screws from outer collar adapter Optional Top Vent Application This appliance is shipped as a rear vent unit. If the...
  • Page 12: General Venting

    Installation of the remote ON/OFF starter switch on • Only Vermont Castings, Majestic Products venting electronic ignition units (Fig. 12): components, specifically approved and labeled for 1. Thread the wiring through the holes on the side this fireplace, may be used.
  • Page 13: General Venting Information-Termination Location

    NOTES: 1 Local codes or regulations may require different clearances. 2 The special venting system used on Vermont Castings, Majestic Products Direct Vent Fireplaces are certified as part of the appliance, with clearances tested and approved by the listing agency.
  • Page 14: Termination Clearances

    Vermont Castings, Majestic Products, 360DVS Series Termination Clearances Termination clearances for buildings with combustible and noncombustible exteriors. Inside Corner Recessed Location Outside Corner Combustible 6" (152 mm) Combustible 6" (152 mm) Noncombustible 2" (51 mm) Noncombustible 2" (51 mm) Balcony...
  • Page 15: General Information For Connecting Vent Pipes

    If vertical dimension from floor of the fireplace is Only venting components manufactured by Vermont Castings, Majestic Products can be used in Direct Vent 11 ft. (3.4 m), horizontal run to the face of outer wall must not exceed 14 ft. (4.3 m).
  • Page 16: Rear Wall Vent Application

    Vermont Castings, Majestic Products, 360DVS Series For combustible walls: Cut a rectangular hole Rear Wall Vent Application measuring 10 in.H x 9 in.W (265 mm x 240 mm) through the exterior wall and frame. Frame in the When installed as a rear vent unit this appliance may opening per Fig.
  • Page 17: Vertical Side Wall Application

    Vermont Castings, Majestic Products, 360DVS Series • If a 90° elbow is used in the horizontal vent run Vertical Sidewall Applications (level height maintained), the maximum horizontal vent length is reduced by 36 in. (914 mm) (Fig. 23). Because it is very important the venting system This does not apply if the 90°...
  • Page 18: Vertical Side Wall Installation

    Vermont Castings, Majestic Products, 360DVS Series STEP 3 Vertical Side Wall Installations Place fireplace into position (Fig. 27). Measure the vertical height (X) required from the base of the flue STEP 1 collars to the center of the wall opening.
  • Page 19: Below Grade Installations

    Vermont Castings, Majestic Products, 360DVS Series STEP 6 5. Apply high-temperature sealant caulking (supplied) Use appropriate length of pipe section—telescopic or around 4 in. and 7 in. snorkel collars. fixed—and install. The 20” (508 mm) section of pipe 6. Slide snorkel into vent pipes and secure to wall.
  • Page 20: Vertical Through-The-Roof Applications

    Vermont Castings, Majestic Products, 360DVS Series Vertical Through-the-Roof 1 + 2 + 3 + 4 = 270 o Applications This Gas Fireplace has been approved for: • Vertical installations up to 40 ft. (12 m) in height. Up to a 10 ft. (3 m) horizontal vent run can be installed within the vent system using a maximum of two 90°...
  • Page 21: Vertical Through-The-Roof Installation

    Vermont Castings, Majestic Products, 360DVS Series If there is a room above ceiling level, a Vertical Through-the-Roof firestop spacer must be installed on both Installation the bottom and the top sides of the ceiling joists (Fig. 36). If an attic is above 1.
  • Page 22: Twist Lock Vent Components

    Vermont Castings, Majestic Products, 360DVS Series Twist Lock Venting Components 7 DVRVT Through-the-Wall Rear Vent Termination Starter Kit Model 7TDVSK—Sidewall/ Rearwall Venting Starter Kit Model 7TDVSKV—Vertical Venting • for 7TDVSKV-A: order 1/12 to 6/12 roof pitch • for 7TDVSKV-B: order 7/12 to 12/12 roof pitch •...
  • Page 23: Crimp End Vent Components

    Vermont Castings, Majestic Products, 360DVS Series Crimped End Venting Components 7 DVRVT Through-the-Wall Rear Vent Termination Starter Kit Model 7DVSK—Sidewall/Rearwall Venting Starter Kit Model 7TDVSKV—Vertical Venting • for 7DVSKV-A: order 1/12 to 6/12 roof pitch • for 7DVSKV-B: order 7/12 to 12/12 roof pitch •...
  • Page 24: Operating Instructions

    Vermont Castings, Majestic Products, 360DVS Series Operating Instructions Glass Information Window Frame Removal Side Window Frame Assemblies Only glass approved by Vermont Castings, Majestic Products should be 1. Shut off the gas supply. used on this fireplace. 2. Allow the fireplace to cool if it has been in operation.
  • Page 25: Glass Cleaning

    3. Place both side panels along the side of the base. and the inner ends rests on top of the other two top NOTE: 360DVS2 is the only 360DV unit that is logs (B44) placed in step 5. fitted with two (2) end verical panels, as shown in Fig.
  • Page 26: Lava Rocks & Ember Material

    Vermont Castings, Majestic Products, 360DVS Series Flame Characteristics It is important to periodically perform a visual check of the pilot and burner flames. Compare them to the pictorials illustrated below (Fig. 45 and Fig. 46). If the flame patterns appear abnormal, contact a qualified service provider for service and adjustment.
  • Page 27: Lighting & Operating Instructions

    Vermont Castings, Majestic Products, 360DVS Series Lighting and Operating Instructions FOR YOUR SAFETY, READ BEFORE LIGHTING. WARNING: If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury or loss of life.
  • Page 28: Lighting & Operating Instructions (En/Ep)

    Vermont Castings, Majestic Products, 360DVS Series Lighting and Operating Instructions For Fireplaces equipped with SIT822 Gas Valve (EN or EP) Warning: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury and loss of life.
  • Page 29: Troubleshooting The Gas Control System

    Vermont Castings, Majestic Products, 360DVS Series Troubleshooting the Gas Control System SIT NOVA 820 MILLIVOLT VALVE NOTE: Before troubleshooting the gas control system, be sure external gas shut off is in the “On” position. WARNING: REMOVE GLASS FRONT BEFORE DOING ANY GAS CONTROL SERVICE WORK.
  • Page 30: Troubleshooting The Gas Control System (En/Ep)

    Vermont Castings, Majestic Products, 360DVS Series Troubleshooting the Gas Control System SIT 822 Valve with a Honeywell Electronic Igniter NOTE: Remove glass before servicing. START TURN GAS SUPPLY OFF. CHECK: LINE VOLTAGE (120VAC). LOW VOLTAGE TRANSFORMER TURN ON/OFF SWITCH (19.5 MINIMUM VAC).
  • Page 31: Troubleshooting: Honeywell Vs8421

    Vermont Castings, Majestic Products, 360DVS Series Troubleshooting: Honeywell VS8421 Honeywell Millivolt Valve START CHECK • SUPPLY LINE HOOKED UP. GAS SUPPLY ON. • SHUTOFF VALVE OPEN. • LOCKOUT HAS ENGAGED. WAIT 60 SECONDS AND TRY AGAIN. • FOR SPARK AT ELECTRODE...
  • Page 32: General Maintenance

    Vermont Castings, Majestic Products, 360DVS Series 8. SIT Top Convertible Pilot General Maintenance Gently lift off pilot hood from the pilot. NOTE: Do Burner and Burner Compartment not remove the spring clip holding the hood in It is important to keep the burner and the burner place.
  • Page 33: Cleaning The Standing Pilot Control System

    Vermont Castings, Majestic Products, 360DVS Series Honeywell Gas Control Valve (Fig. 49) Cleaning the The Honeywell valve fitted to this unit is suitable for Standing Pilot Control System use with LP or Natural Gas. It is converted to the The burner and control system consists of: required gas application by installing a color-coded conversion screw.
  • Page 34: Replacement Parts Pictorial

    1c (x2) 1a (x2) 1d (x2) 3a/b 16a/b 15a/b 33a/b 36a/b 2547/ 503 Vermont Castings, Majestic Products reserves the right to make changes in design, materials, specifications, prices and discontinue colors and products at any time, without notice. 360DVS Series 10002547...
  • Page 35: Replacement Part Numbers

    Vermont Castings, Majestic Products, 360DVS Series 360DVS Series (Items marked ‘*’ are not shown in the parts illustration) Ref. Description 360DVS2 360DVS3 360DVSL 360DVSR Log Set (complete) 10002523 10002523 10002523 10002523 Log - left rear & right front Log - left front & right rear Log - left front top &...
  • Page 36 Vermont Castings, Majestic Products, 360DVS Series 360DVS Series (continued) (Items marked ‘*’ are not shown in the parts illustration) Ref. Description 360DVS2 360DVS3 360DVSL 360DVSR Remote ON/OFF switch (RN/RP models) 51842 51842 51842 51842 Wiring Harness (remote switch) 55923 55923...
  • Page 37: Replacement Parts

    Vermont Castings, Majestic Products, 360DVS Series Optional Accessories Available Maintenance Fan Kits The fan itself does not require regular maintenance; however, periodic cleaning of the fan and the FK24 Fan Assembly surrounding area is required. This auxiliary fan system increases the efficiency of the circulation of the heated air.
  • Page 38: Remote Controls

    24-hour clock Wall-mounted thermostat control Decorative Trim Frame Kit The DV360TKMP Medium Trim Kit in polished brass is available for the 360DVS2 model only. Top deflector plate Each kit contains 4 polished brass trim pieces and the DV360TKMP necessary attaching screws to frame one side window of the unit.
  • Page 39: Warranty

    Vermont Castings, Majestic Products, 360DVS Series PRODUCT COVERED BY THIS WARRANTY All Vermont Castings gas stoves, gas inserts, and gas fireplaces, and all Majestic or Northern Flame brand gas fireplaces equipped with an Insta-Flame Ceramic Burner, or standard steel tube burner.

This manual is also suitable for:

360dvsl360dvs3360dvsr

Table of Contents