A. Vent Components Diagrams (continued)
Note: Heat shields MUST overlap by a minimum of 1-1/2 in. (38 mm). The heat shield is designed to be
used on a wall 4 in. to 7-1/4 in. (102 mm to 184 mm) thick. If wall thickness is less than 4 in. (102 mm) the
existing heat shields must be field trimmed. If wall thickness is greater than 7-1/4 in. (184 mm) a DVP-HSM-B
will be required.
15-1/8 in.
(384 mm)
12 in.
(305 mm)
Can adjust 2-1/8 in. (4-1/4 to 6-3/8)
Figure 12.2 DVP Vent Components
Majestic • QUARTZPLA36IN / QUARTZPLA36IL Installation Manual • 2643-980 Rev. B • 7/22
68
(203 mm)
*5 in.
(127 mm)
DVP-TRAP
Horizontal Termination Cap
DVP-TRAP1
DVP-TRAPK1
DVP-HPC1
8 in.
Heat
Shield
Term Cap
Max
Effective
Length
Can adjust 4-1/8 in. (6-3/8 to 10-1/2)
* Center of the horizontal vent pipe to
the vertical measuring surface.
Minimum
Effective Length
3-1/8 in.
Trap1
79 mm
5-3/8 in.
Trap2
137 mm
DVP-TRAP2
DVP-TRAPK2
DVP-HPC2
Maximum
Effective Length
4-5/8 in.
117 mm
9-3/8 in.
238 mm