7.1.5
Always run the inverter in a clean status.
When cleaning the inverter, gently wipe dirty areas with a soft cloth immersed in neutral detergent or ethanol.
NOTE
• Do not use solvent, such as acetone, benzene, toluene and alcohol, as these will cause the inverter surface paint to peel off.
• The display, etc. of the operation panel (FR-DU08) and parameter unit (FR-PU07) are vulnerable to detergent and alcohol.
Therefore, avoid using them for cleaning.
7.1.6
The inverter consists of many electronic parts such as semiconductor devices.
The following parts may deteriorate with age because of their structures or physical characteristics, leading to reduced
performance or fault of the inverter. For preventive maintenance, the parts must be replaced periodically.
Use the life check function as a guidance of parts replacement.
Cooling fan
Main circuit smoothing capacitor
On-board smoothing capacitor
Relays
Main circuit fuse inside the inverter (FR-A840-
04320(160K) or higher)
*1
Estimated lifespan for when the yearly average surrounding air temperature is 40°C.
(without corrosive gas, flammable gas, oil mist, dust and dirt etc.)
*2
Output current: 80% of the inverter rating
NOTE
• For parts replacement, contact the nearest Mitsubishi FA center.
 Inverter parts life display
The inverter diagnoses the main circuit capacitor, control circuit capacitor, cooling fan, and inrush current limit circuit by itself
and estimates their lives.
The self-diagnostic warning is output when the life span of each part is near its end. It gives an indication of replacement time.
Guideline for life judgment using the life warning output
Main circuit capacitor
Control circuit capacitor
Inrush current limit circuit
Cooling fan
Downloaded from
ManualsNet.com
Converter module
D1
D2
R/L1
S/L2
T/L3
D4
D5

Cleaning

Replacement of parts

Part name
10 years
10 years
10 years
10 years
Part
85% of the initial capacity
Estimated remaining life 10%
Estimated remaining life 10% (Power ON: 100,000 times left)
Less than the specified speed
search engine
P/+
Inverter module
TR1
TR3
D3
C
D6
TR4
TR6
N/−
*1
Estimated lifespan
*2
*2
Judgment level
7. PRECAUTIONS FOR MAINTENANCE AND INSPECTION
TR5
U
V
W
TR2
Description
Replace (as required)
Replace (as required)
Replace the board (as required).
As required
Replace (as required)
7.1 Inspection item
1
2
3
4
5
6
7
8
9
10