6.3

Check and clear of the fault history

The operation panel stores the fault indications which appear when a protective function is activated to display the fault record
for the past 8 faults (fault history).
 Check for the fault history
Monitor mode
Fault history mode
Fault record 1
Fault record 2
Fault record 8
When the fault history is
empty, "E0" is displayed.
*1
When an overcurrent trip occurs by an instantaneous overcurrent, the monitored current value saved in the fault history may be lower than the
actual current that has flowed.
*2
The cumulative energization time and actual operation time are accumulated from 0 to 65535 hours, then cleared, and accumulated again from 0.
774
6. PROTECTIVE FUNCTIONS
6.3 Check and clear of the fault history
Downloaded from
ManualsNet.com
Parameter setting mode
[Operation for displaying fault history]
The last eight fault records can be displayed.
(On the display of the last fault record (fault record 1), a decimal point LED is ON.)
Press the
setting dial.
Fault record number
Latest fault
Fault record number
Second latest fault
Press the
setting dial.
Fault record number
Eighth latest fault
Press the
setting dial.
search engine
Function mode
Output frequency
Blinking
Time
Blinking
Day
Blinking
Month
Blinking
Output current 
Blinking
Output voltage
Blinking
Cumulative
energization time 
Blinking
Year
Blinking

Hide quick links: