4.2
4.2.1
• Press
and output voltage.
Operating procedure
1.
Press
2.
Press
whether the inverter is running or at a stop. The unit of current "A" appears.
3.
Press
NOTE
• Other monitor item, such as output power or set frequency, is also available. Use Pr.52 Operation panel main monitor
selection or Pr.774 Operation panel monitor selection 1 to Pr.776 Operation panel monitor selection 3 to change the
setting. (Refer to
4.2.2
The first priority monitor screen, which is displayed first when the operation panel becomes in the monitor mode, is selectable.
To set it, press
The following show the procedure to set the monitor screen displaying the output current as the first priority monitor screen.
Operating procedure
1.
Change the mode of the operation panel to the monitor mode, and switch the monitor screen to the one on which
the output current can be monitored.
2.
Press
3.
When the operation panel is in the monitor mode next time, the output current monitored value is displayed first.
NOTE
• Use Pr.52 Operation panel main monitor selection or Pr.774 Operation panel monitor selection 1 to Pr.776 Operation
panel monitor selection 3 to change the monitor item. (Refer to
4.2.3
To display the present set frequency, change the mode of the operation panel to the monitor mode and press the setting dial
(
) while the inverter runs in the PU operation mode or in the External/PU combined operation mode 1 (Pr.79 Operation
mode selection = "3").
NOTE
• Use Pr.992 Operation panel setting dial push monitor selection to change the item to be displayed. (Refer to
Downloaded from
ManualsNet.com

Monitoring the inverter

Monitoring of output current and output voltage

on the operation panel in the monitor mode to switch the monitor item between output frequency, output current,
during inverter operation to monitor the output frequency. [Hz] indicator turns ON.
to monitor the output current. This operation is valid under any operation mode of the inverter and
to monitor the output voltage. The unit of voltage "V" appears.
page
446.)

First priority monitor screen

for a while when the desired monitor item is displayed on a monitor screen.
for a while (1 second). The output current monitor screen is set as the first priority monitor screen.

Displaying the set frequency