5.7

(E) Environment setting parameters

To set the time
To set a limit for the reset function.
To shut off output if the operation panel
disconnects.
To force deceleration to a stop on the
operation panel.
To select the display language of the
parameter unit
To control the buzzer of the parameter unit and
operation panel
To adjust the LCD contrast of the parameter
unit
To turn OFF the operation panel when not
using it for a certain period of time
To switch the monitor display of the operation
panel to the PID set point setting screen by
simply turning the setting dial
To use the USB memory
To use the setting dial of the operation panel
like a potentiometer to set the frequency.
To disable the operation panel.
To change the frequency change increments
which changes when using the setting dial of
the operation panel
To use the regeneration unit to increase the
motor braking torque
To change the overload current rating
specification
To input a voltage between 480 V and 500 V
To prevent parameter rewriting
To restrict parameters with a password
To use parameters freely
To change parameter settings for an IPM motor
as a batch
To set multiple parameters by batch
To display the required parameters
To release the Parameter copy warning (CP)
To reduce the motor noise and EMI
To understand the maintenance time of
inverter parts and peripheral devices
5.7.1

Real time clock function

The time can be set. The time can only be updated while the inverter power is ON.
334
5. PARAMETERS
5.7 (E) Environment setting parameters
Downloaded from
ManualsNet.com
Purpose
Real time clock function
Reset selection/
disconnected PU
detection/PU stop
selection/reset limit
PU display language
selection
PU buzzer control
PU contrast adjustment
Display-off setting
Direct setting
USB host reset
Operation panel operation
selection
Frequency change
increment amount setting
Regenerative brake
selection
Multiple rating setting
Input voltage mode
selection
Parameter write disable
selection
Password
Free parameter
IPM parameter initialization P.E430
Automatic parameter
setting
Applicable parameter
display and user group
function
Parameter copy alarm
release
PWM carrier frequency
changing
Inverter parts life display
Maintenance output
function
Current average monitor
search engine
Parameter to set
P.E020 to P.E022
Pr.1006 to Pr.1008
P.E100 to P.E102,
Pr.75
P.E107
P.E103
Pr.145
P.E104
Pr.990
P.E105
Pr.991
P.E106
Pr.1048
P.E108
Pr.1000
P.E110
Pr.1049
P.E200
Pr.161
P.E201
Pr.295
P.E300, P.G107
Pr.30, Pr.70
P.E301
Pr.570
P.E302
Pr.977
P.E400
Pr.77
P.E410, P.E411
Pr.296, Pr.297
P.E420, P.E421
Pr.888, Pr.889
Pr.998
P.E431
Pr.999
Pr.160, Pr.172 to
P.E440 to P.E443
Pr.174
P.E490
Pr.989
Pr.72, Pr.240,
P.E600 to P.E602
Pr.260
Pr.255 to Pr.259,
P.E700 to P.E705
Pr.506
Pr.503 to Pr.504,
P.E710 to P.E715
Pr.686 to Pr.689
P.E720 to P.E722
Pr.555 to Pr.557
Refer to
page
334
336
339
340
340
340
340
341
341
342
724
343
345
345
348
350
231
350
354
744
356
359
363
363