Offline Auto Tuning For A Frequency Search - Mitsubishi Electric FR-A800 Series Instruction Manual

Hide thumbs Also See for FR-A800 Series:
Table of Contents

Advertisement

CAUTION
• An IPM motor is a motor with interior permanent magnets. High voltage is generated at motor terminals while the motor
is running.
Do not touch motor terminals and other parts until the motor stops to prevent an electric shock.
• When the automatic restart after instantaneous power failure function is selected, the motor suddenly starts (after reset
time passes) when an instantaneous power failure occurs.
Stay away from the motor and machinery.
Apply the supplied CAUTION stickers to easily visible places when automatic restart after instantaneous power failure
has been selected.
Parameters referred to
Pr.13 Starting
frequencypage
Pr.65, Pr.67 to Pr.69 Retry
Pr.78 Reverse rotation prevention
Pr.178 to Pr.189 (Input terminal function
Pr.882 Regeneration avoidance operation

5.14.16 Offline auto tuning for a frequency search

V/F
V/F
V/F
PM
PM
PM
Under V/F control or when driving the IPM motor MM-CF, the accuracy of the "frequency search", which is used to detect the
motor speed for the automatic restart after instantaneous power failure and flying start, can be improved.
Pr.
Name
Automatic restart after
162
instantaneous power
A700
failure selection
298
Frequency search gain 9999
*1
A711
560
Second frequency
*1
search gain
A712
96
Auto tuning setting/
C110
status
90
Motor constant (R1)
C120
463
Second motor auto
C210
tuning setting/status
458
Second motor
C220
constant (R1)
*1
Tuning is not available under PM sensorless vector control.
*2
For the FR-A820-03160(55K) or lower, and FR-A840-01800(55K) or lower.
638
5. PARAMETERS
5.14 (A) Application parameters
Downloaded from
ManualsNet.com
381,
page 382
functionpage 426
selectionpage 406
selection)page 521
selectionpage 732
Initial
Setting range
value
0, 1000
1, 1001
2, 1002
3, 1003
0
10, 1010
11, 1011
12, 1012
13, 1013
0 to 32767
9999
0 to 32767
9999
9999
0
1, 101
0
11
0 to 50 Ω, 9999
9999
0 to 400 mΩ, 9999
0
1, 101
0
11
0 to 50 Ω, 9999
9999
0 to 400 mΩ, 9999
search engine
Frequency search only performed at the first start
Reduced voltage start only at the first start (no frequency search)
Encoder detection frequency search
Frequency search only performed at the first start (reduced impact
restart)
Frequency search at every start
Reduced voltage start at every start (no frequency search)
Encoder detection frequency search at every start
Frequency search at every start (reduced impact restart)
The offline auto tuning automatically sets the gain required for the
frequency search.
The constant value of Mitsubishi Electric motor (SF-PR, SF-JR, SF-
HR, SF-JRCA, SF-HRCA, or MM-CF) is used.
The offline auto tuning automatically sets the gain required for the
frequency search of the second motor.
The constant value of Mitsubishi Electric motor (SF-PR, SF-JR, SF-
HR, SF-JRCA, SF-HRCA, or MM-CF) is used for the second motor.
No offline auto tuning
Offline auto tuning is performed under Advanced magnetic flux
vector control, Real sensorless vector control, or Vector control.
(Refer to
page 532
and
Offline auto tuning is performed without rotating the motor (for IPM
motor MM-CF).
*2
Tuning data (The value measured by offline auto tuning is
automatically set.)
9999: The constant value of Mitsubishi Electric motor (SF-PR, SF-
*3
JR, SF-HR, SF-JRCA, SF-HRCA and so on) is used.
No auto tuning for the second motor.
Offline auto tuning is performed for the second motor. (Refer to
532
and
page
542.)
Offline auto tuning is performed without rotating the second motor
(under V/F control or PM sensorless vector control (IPM motor MM-
CF)).
*2
Tuning data of the second motor (same asPr.90)
*3
Description
page
542.)
page

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents