Clearing a parameter from a user group (Pr.174)
• To delete Pr.3 from a user group.
Operating procedure
1.
Power ON
Make sure the motor is stopped.
2.
Changing the operation mode
Press
3.
Selecting the parameter setting mode
Press
4.
Selecting a parameter
Turn
5.
Parameter read
Press
6.
Clearing the parameter
Turn
"
To continue deleting parameters, repeat steps 5 and 6.
NOTE
• Pr.77 Parameter write selection, Pr.160, Pr.296 Password lock level, Pr.297 Password lock/unlock and Pr.991 PU
contrast adjustment can always be read regardless of the user group setting. (For Pr.991, only when the FR-LU08 or the
FR-PU07 is connected.)
• Pr.77, Pr.160, Pr.172 to Pr.174, Pr.296, and Pr.297 cannot be registered in a user group.
• When Pr.174 is read, "9999" is always displayed. "9999" can be written, but it does not function.
• Pr.172 is disabled if set to a value other than "9999".
Parameters referred to
Pr.15 Jog frequency, Pr.16 Jog acceleration/deceleration
Pr.77 Parameter write
Pr.296 Password lock level, Pr.297 Password
Pr.550 NET mode operation command source
Pr.551 PU mode operation command source
Pr.991 PU contrast
adjustmentpage 340
5.7.18 PWM carrier frequency and Soft-PWM control
The motor sound can be changed.
Pr.
72
PWM frequency selection
E600
240
Soft-PWM operation
E601
selection
260
PWM frequency automatic
E602
switchover
*1
The setting range of the FR-A820-03160(55K) or lower and the FR-A840-01800(55K) or lower
*2
The setting range of the FR-A820-03800(75K) or higher and the FR-A840-02160(75K) or higher
356
5. PARAMETERS
5.7 (E) Environment setting parameters
Downloaded from
ManualsNet.com
to choose the PU operation mode. [PU] indicator turns ON.
to choose the parameter setting mode. (The parameter number read previously appears)
until "
" (Pr.174) appears.
. "
" appears.
until "
" (Pr.3) appears. Press
" and "
"are displayed alternately.
selectionpage 345
lock/unlockpage 348
selectionpage 400
selectionpage 400
Initial
Name
value
2
1
1
search engine
to delete the parameter.
timepage 410
Setting range
The PWM carrier frequency can be changed. The setting value
*1
0 to 15
represents the frequency in kHz. However, "0" indicates 0.7
kHz, "15" indicates 14.5 kHz, and "25" indicates 2.5 kHz.
*2
0 to 6, 25
(The setting value "25" is for the sine wave filter only.)
0
Soft-PWM control disabled.
1
Soft-PWM control enabled.
PWM carrier frequency automatic reduction function disabled
0
(for the LD, ND, or HD rating)
1
PWM carrier frequency automatic reduction function enabled
Description