Daikin VRV RXYMQ-A Series Service Manual page 164

R-410a heat pump 50/60 hz
Table of Contents

Advertisement

Troubleshooting by Error Code
Error code
JA - 06
Defective high pressure sensor: Open
Defective high pressure sensor: Short
JA - 07
JC - 06
Defective low pressure sensor: Open
Defective low pressure sensor: Short
JC - 07
L1 - 01
IPM error: Compressor M1C
L1 - 02
Defective current sensor: Compressor M1C
L1 - 03
Current offset: Compressor M1C
L1 - 04
IGBT error: Compressor M1C
L1 - 05
Jumper settings error: Compressor M1C
L1 - 36
EEPROM abnormality: Compressor M1C
L1 - 47
Power supply voltage abnormality: Compressor M1C
L2 - 01
Momentary power failure
L2 - 04
Power ON
L4 - 01
Radiation fin temperature rise: Inverter for M1C
L4 - 06
Radiation fin temperature rise: Inverter fan M1F
Current offset error
L5 - 03
Compressor M1C overcurrent error
L8 - 03
L9 - 01
Compressor M1C startup error
Compressor M1C output open phase
L9 - 13
LC - 14
PCB inverter error (Compressor M1C)
LC - 19
PCB inverter error (Fan M1F)
Inverter circuit capacitor high voltage
P1 - 01
Unbalanced power supply voltage
P3 - 01
Defective reactor thermistor 1
P3 - 04
Defective reactor thermistor 2
P4 - 01
Defective radiation fin thermistor
P4 - 02
Defective fan M1F fin sensor
PJ - 04
Incorrect type of compressor
PJ - 09
Incorrect type of fan
U0 - 05
Refrigerant shortage warning (cooling)
U0 - 06
Refrigerant shortage warning (heating)
U0 - 08
Refrigerant shortage
U1 - 16
Open phase for power supply
U1 - 19
Hz error for power supply
U2 - 01
Shortage of inverter power supply voltage
U2 - 02
Power phase loss
Initial installation alarm / Test operation failed due to
U3 - 02
indoor unit error
U3 - 03
Test operation not conducted
U3 - 04
Abnormal end of test operation
Premature end of test operation during initial
U3 - 05
transmission error – check indoor unit error U4 / U9
Premature end of test operation during normal
U3 - 06
transmission error
Premature end of test operation due to transmission
U3 - 07
error
Premature end of test operation due to transmission
U3 - 08
error of all units
System refrigerant auto charge operation not yet
U3 - 10
executed
Transmission error between indoor unit and outdoor
U4 - 01
unit
Transmission error between indoor unit and system:
U4 - 03
check indoor unit error
158
Description of error
Troubleshooting
Refer to the JA flowchart and make a diagnosis
on the Error code shown to the left.
Refer to the JC flowchart and make a diagnosis
on the Error code shown to the left.
The inverter PCB may be defective or a PCB other than
the specified is mounted.
Refer to the L1 flowchart and make a diagnosis based
on the Error code shown to the left.
Refer to the L2 flowchart and make a diagnosis based on
the Error code shown to the left.
Refer to the L4 flowchart and make a diagnosis based
on the Error code shown to the left.
Refer to the L5 flowchart and make a diagnosis based
on the Error code shown to the left.
Refer to the L8 flowchart and make a diagnosis
of the compressor based
on the Error code shown to the left.
Refer to the L9 flowchart and make a diagnosis
of the compressor based
on the Error code shown to the left.
Refer to the LC flowchart and make a diagnosis based
on the Error code shown to the left.
Refer to the P1 flowchart and make a diagnosis based
on the Error code shown to the left.
Refer to the P3 flowchart and make a diagnosis based on
the Error code shown to the left.
Refer to the P4 flowchart and make a diagnosis based
on the Error code shown to the left.
Refer to the PJ flowchart and make a diagnosis based
on the Error code shown to the left.
Refer to the U0 flowchart and make a diagnosis based
on the Error code shown to the left.
Refer to the U1 flowchart and make a diagnosis based on
the Error code shown to the left.
Refer to the U2 flowchart and make a diagnosis based
on the Error code shown to the left.
Refer to the U3 flowchart and make a diagnosis based
on the Error code shown to the left.
Refer to the U4 flowchart and make a diagnosis based
on the Error code shown to the left.
SiME332106E
Diagnosis
of the sensor based
of the sensor based
Part 6 Service Diagnosis