Panasonic AJ-HD1700PE Operating Instructions Manual page 9

Table of Contents

Advertisement

Parts and Their Functions
Front panel
<
8
9
: =
POWER
OFF
ON
1
2
3
4
5
6
7
8
CUE
CH
CH CONDITION
MONITOR
FULL/FINE
REMOTE
9P
50P
RS-232C
L
R
HEADPHONES
SHIFT
F1
F2
F3
ABC
DEF
GHI
AUDIO CH SELECT
7
8
9
1
5
2
6
3
7
4
8
CH
CH
CH
CH
CH
CH
CH
CH
PREVIEW/
JKL
MNO
PQRS
REVIEW
4
5
6
BS
AUTO
TUV
WXYZ
EDIT
1
2
3
ENT
PUSH
LOCK
0
C
T
F
REC
P8
REC
P8
REC
P8
REC
P8
FULL
8 MONITOR SELECT buttons
These buttons are used to select the audio signals
which are to be output to the monitor L and R
connectors and headphones jack.
• When OFF has been selected as the
MIX setting on the <AUDIO SHIFT2> menu
(factory setting):
Each time the L (or R) button is pressed, the
signal to be output to the monitor L (or R)
connector is changed in the following sequence
and displayed on the audio level meter: CH1 >
CH2 > CH3> CH4 > CH5 > CH6 > CH7 >
CH8 > CUE > CH1, etc.
• When L, R or L/R has been selected as the
M MIX setting on the <AUDIO SHIFT2> menu:
At this setting, the signals of a multiple number of
channels can be mixed and output.
When the number key corresponding to the
channel whose signals are to be monitored is
pressed while the L (or R) button is held down,
that channel is selected and its signals are
displayed on the audio level meter.
performing the same operation, the selected
channel can be de-selected.)
However, a maximum of only two channels from
CH1 to CH4 and a maximum of only two
channels from CH5 to CH8 can be selected.
Example of channels which can be selected:
CH1 i CH3 i CH5 iCH8 " OK
CH1 + CH2 + CH4 " NG
9 METER (FULL/FINE) selector button
This button is used to select the scale display for the
audio level meter.
FULL mode: Depending on the setting selected for the
setup menu item No.763 (METER SCALE)*, either the
j¶ to 0 dB (reference level: j20 dB/j18 dB**) or j¶
to i20 dB (reference level: 0 dB) range is displayed.
FINE mode: Depending on the setting selected for the
setup menu item No.763 (METER SCALE)*, either the
j24 to j15 dB (reference level: j20 dB/j18 dB**) or
j4 to i5 dB (reference level: 0 dB) range is displayed
on a scale with 0.5 dB increments.
*
This menu is not displayed for AJ-HD1700E.
** j20 dB is applied for AJ-HD1700P and j18 dB is for AJ-HD1700E.
;
EJECT
XL/L/M
-cassette
Do not insert S-cassette
without adapter
SHTL
JOG
VAR
ADJUST
HOME
RF1
RF2
ASSEM
PUSH-INTER
VIDEO
TC
CUE
UNITY
INSERT
REV
FWD
AUDIO
UNITY
DIAG
MENU
STAND BY
PLAYER
RECORDER INPUT CHECK
F4
F5
F6
SERVO
REC INHIBIT
EDIT
PLAY
REC
A IN
A OUT
PRE-
ROLL
TRIM
REW
STOP
FF
SET
IN
OUT
FULL
F6
: REMOTE buttons and RS-232C display
These buttons are used when this VTR is to be
controlled from an external component using the
REMOTE, RS-232C or parallel connector.
9P:
When this button is pressed for 2 or more
seconds, its LED lights, and the 9-pin REMOTE
connector is selected.
50P: When this button is pressed for 2 or more
seconds, its LED lights, and it is possible to control
the VTR from a unit which has been connected using
the 50-pin parallel mode connector.
RS-232C display: This LED lights when communi-
cation has been enabled between the VTR and the
unit which has been connected to the RS-232C
connector.
; AUTO OFF lamp
M
This lamp lights when a problem has occurred with
the VTR's operation, and details of the problem
appear on the time code display.
< LCD monitor
This monitor is used to check the tape's playback
pictures and EE pictures.
When an HD tape is played back, the signals are down-
converted and displayed in the letter-box screen format.
When an SD tape is played back, the signals are
F6
displayed using a 4:3 aspect ratio.
On-screen menus can also be displayed on the monitor.
If the VTR is left in a state where no controls on the front
panel are operated or where the tape is not running, the
monitor display is automatically turned off in order to
protect the monitor. When the next VTR operation is
started, the monitor display comes back on.
(By
<Note>
Although the LCD monitor has been manufactured
using technology with extremely high levels of
precision, some pixels may be missing from parts of
the screen or some pixels may remain lighted.
These missing or lighted pixels will not be recorded.
It should also be borne in mind that this is not
indicative of a malfunction.
= Function buttons
These buttons are used to perform the operations of
the function menus (see page 38 for details) and
setup menus.
: This is used to switch the pages of the current
SHIFT
function menu (
to
: These are used to change the settings of
F1
F6
the setting items enclosed in the frame at the bottom of
the time code display.
To change a setting, keep pressing the corresponding
function button (
numerical value appears; alternatively, press the
corresponding function button to highlight the setting of
the setting item, and then turn the ADJUST dial until
the desired numerical value is obtained.
to
).
F1
F6
to
) until the desired
F1
F6
9

Advertisement

Table of Contents
loading

Table of Contents