Code
[2.D.1]
[F-0B]
The shut off valve:
▪ 0 No: is NOT influenced by heating
demand.
▪ 1 Yes: closes when there is NO
heating demand.
INFORMATION
The setting [F‑0B] is only valid when there is a thermostat
or external room thermostat request setting (NOT in case
of leaving water temperature setting).
8.4.4

Additional zone

Setpoint screen
You can set the leaving water temperature for the additional zone
using the setpoint screen. For more information about how to do this,
see
"8.3.5 Setpoint screen" on
page 47.
Schedule
Indicates if the desired leaving water temperature is according to a
schedule. Also see
"8.4.3 Main zone" on
#
Code
Schedule
[3.1]
N/A
▪ 0: No
▪ 1: Yes
Heating schedule
You can set the additional zone heating temperature schedule using
the schedule screen. For more information about this screen, see
"8.3.8 Schedule screen: Example" on
Setpoint mode
The setpoint mode of the additional zone can be independently set
from the setpoint mode of the main zone, see
page 51.
#
Code
[3.4]
N/A
Setpoint mode
▪ 0: Fixed
▪ 1: WD heating, fixed cooling
▪ 2: Weather dependent
Heating WD curve
Set weather-dependent heating for the additional zone (if [3.4] = 1 or
2):
ERGA04~08DAV3(A) + EHVZ04+08S18+23DA +
EHVZ04+08S18+23DJ
Daikin Altherma 3 R F
4P495249-1B – 2019.06
Description
page 51.
Description
page 48.
"Setpoint mode"  on
Description
#
Code
[3.5]
[0-00]
Set weather-dependent heating:
T t
[0-01]
[0-02]
[0-01]
[0-03]
[0-00]
▪ T
: Target leaving water temperature
t
(additional zone)
▪ T
: Outdoor temperature
a
▪ [0-03]:
temperature. –40°C~+5°C
▪ [0-02]:
temperature. 10°C~25°C
▪ [0-01]:
temperature
temperature equals or drops below the
low
[9‑05]°C~[9‑06]°C
Note: This value should be higher
than
temperatures
required.
▪ [0-00]:
temperature
temperature equals or rises above the
high
[9‑05]~min(45, [9‑06])°C
Note: This value should be lower than
[0‑01]
temperatures less warm water is
required.
Emitter type
For more info about this functionality, see
page 51.
#
Code
[3.7]
[2‑0D]
Emitter type
▪ 0: Underfloor heating
▪ 1: Fancoil unit
▪ 2: Radiator
The setting of the emitter type has an influence on the space heating
setpoint range and the target delta T in heating as follows:
Emitter type
Space heating
setpoint range
Additional zone
[9‑05]~[9‑06]
0: Underfloor
Maximum 55°C
heating
1: Fancoil unit
Maximum 55°C
2: Radiator
Maximum 65°C
Setpoint range
For more information about this setting, also see
zone" on
page 51.
#
Code
Leaving water temperature range for the additional leaving water
temperature zone (= the leaving water temperature zone with the
highest leaving water temperature in heating operation)
8 Configuration
Description
[0-03]
[0-02]
T a
Low
outdoor
ambient
High
outdoor
ambient
Desired
leaving
water
when
the
outdoor
ambient
temperature.
[0‑00]
as
for
low
outdoor
warmer
water
is
Desired
leaving
water
when
the
outdoor
ambient
temperature.
as
for
high
outdoor
"8.4.3  Main zone"  on
Description
Target delta T in
heating [1‑0C]
Variable (see [2.B])
Variable (see [2.B])
Fixed 10°C
"8.4.3  Main
Description
Installer reference guide
55