Daikin ERGA08DAV3 Installer's Reference Manual page 96

Hide thumbs Also See for ERGA08DAV3:
Table of Contents

Advertisement

4/9
Field settings table
Breadcrumb
Field code
Setting name
└─ Backup heater
9.1
[5-0D]
Voltage
9.1
[4-0A]
Configuration
9.1
[6-03]
Capacity step 1
9.1
[6-04]
Additional capacity step 2
└─ Main zone
9.1
[2-0C]
Emitter type
9.1
[C-07]
Control
9.1
Setpoint mode
9.1
Schedule
9.1
[1-00]
Low ambient temp. for LWT main zone heating WD curve.
9.1
[1-01]
High ambient temp. for LWT main zone heating WD curve.
9.1
[1-02]
Leaving water value for low ambient temp. for LWT main zone heating WD curve.
9.1
[1-03]
Leaving water value for high ambient temp. for LWT main zone heating WD curve.
9.1
[1-06]
--
9.1
[1-07]
--
9.1
[1-08]
--
9.1
[1-09]
--
└─ Additional zone
9.1
[2-0D]
Emitter type
9.1
Setpoint mode
9.1
Schedule
9.1
[0-00]
Leaving water value for high ambient temp. for LWT add zone heating WD curve.
9.1
[0-01]
Leaving water value for low ambient temp. for LWT add zone heating WD curve.
9.1
[0-02]
High ambient temp. for LWT add zone heating WD curve.
9.1
[0-03]
Low ambient temp. for LWT add zone heating WD curve.
9.1
[0-04]
--
9.1
[0-05]
--
9.1
[0-06]
--
9.1
[0-07]
--
└─ Tank
9.1
[6-0D]
Heat up mode
9.1
[6-0A]
Comfort setpoint
9.1
[6-0B]
Eco setpoint
9.1
[6-0C]
Reheat setpoint
└─ Domestic hot water
9.2.1
[E-05]
Domestic hot water
[E-06]
[E-07]
9.2.2
[D-02]
DHW pump
9.2.4
[D-07]
Solar
└─ Back up heater
9.3.1
[E-03]
BUH type
9.3.2
[5-0D]
Voltage
9.3.3
[4-0A]
Configuration
9.3.4
[6-03]
Capacity step 1
9.3.5
[6-04]
Additional capacity step 2
9.3.6
[5-00]
Equilibrium
4P495259-1B - 2019.06
R/W (*2)
R/O (*1)
(*3)
R/W
R/W
R/O (*1)
R/W (*2)
(*3)
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/O
R/W
R/W
R/O
R/W (*2)
R/O (*1)
(*3)
R/W
R/W
R/O (*1)
R/W (*2)
(*3)
R/W
(#) Setting is not applicable for this unit.
Range, step
Default value
0: 230V, 1~ (*1) (*2)
1: 230V, 3~ (*2)
2: 400V, 3~ (*3)
0: 1 (*1)
1: 1/1+2 (*2) (*3)
2: 1/2
3: 1/2 + 1/1+2 in emergency
0~10kW, step: 0,2kW
2kW (*2)
3kW (*1)(*3)
0~10kW, step: 0,2kW
0kW (*1)
4kW (*2)
6kW (*3)
0: Underfloor heating
1: Fancoil unit
2: Radiator
0: LWT control
1: Ext RT control
2: RT control
0: Fixed
2: Weather dependent
0: No
1: Yes
-40~5°C, step: 1°C
-10°C
10~25°C, step: 1°C
15°C
[9-01]~[9-00], step: 1°C
35°C
[9-01]~min(45, [9-00])°C , step: 1°C
25°C
20
35
22
18
0: Underfloor heating
1: Fancoil unit
2: Radiator
0: Fixed
2: Weather dependent
0: No
1: Yes
[9-05]~min(45,[9-06])°C, step: 1°C
35°C
[9-05]~[9-06]°C, step: 1°C
50°C
10~25°C, step: 1°C
15°C
-40~5°C, step: 1°C
-10°C
8
12
35
20
0: Reheat only
1: Reheat + sched.
2: Scheduled only
30~[6-0E]°C, step: 1°C
60°C
30~min(50, [6-0E])°C, step: 1°C
45°C
30~min(50, [6-0E])°C, step: 1°C
45°C
3: Integrated
0: No
1: Secondary rtrn
2: Disinf. Shunt
0: No
1: Yes
2: 3V (*1)
3: 6V (*2)
4: 9W (*3)
0: 230V, 1~ (*1) (*2)
1: 230V, 3~ (*2)
2: 400V, 3~ (*3)
0: 1 (*1)
1: 1/1+2 (*2) (*3)
2: 1/2
3: 1/2 + 1/1+2 in emergency
0~10kW, step: 0,2kW
2kW (*2)
3kW (*1)(*3)
0~10kW, step: 0,2kW
0kW (*1)
4kW (*2)
6kW (*3)
0: Allowed
1: Not allowed
Installer setting at variance with
default value
Date
Value
(*1) *3V_
(*2) *6V_
(*3) *9W