User
0000
To access the installer settings
1 Set the user permission level to Installer.
2 Go to [9]: Installer settings.
To modify an overview setting
Example: Modify [1‑01] from 15 to 20.
Most settings can be configured via the menu structure. If for any
reason it is required to change a setting using the overview settings,
then the overview settings can be accessed as follows:
1 Set the user permission level to Installer. See
change the user permission level" on
2 Go to [9.I]: Installer settings > Overview
field settings.
3 Turn the left dial to select the first part of the setting
and confirm by pressing the dial.
00
05
0A
01
06
0B
0
1
02
07
0C
2
03
08
0D
3
04
09
0E
4 Turn the left dial to select the second part of the
setting
00
05
0A
01 15
06
0B
1
02
07
0C
03
08
0D
04
09
0E
5 Turn the right dial to modify the value from 15 to 20.
00
05
0A
01 20
06
0B
1
02
07
0C
03
08
0D
04
09
0E
6 Press the left dial to confirm the new setting.
7 Press the center button to go back to the home
screen.
INFORMATION
When you change the overview settings and you go back
to the home screen, the user interface will show a popup
screen and request to restart the system.
When confirmed, the system will restart and recent
changes will be applied.
8.2

Configuration wizard

After first power ON of the system, the user interface will guide you
using the configuration wizard. This way you can set the most
important initial settings. This way the unit will be able to run
properly. Afterwards, more detailed settings can be done via the
menu structure if required.
ERGA04~08DAV3(A) + EHVZ04+08S18+23DA +
EHVZ04+08S18+23DJ
Daikin Altherma 3 R F
4P495249-1B – 2019.06
"To
page 44.
You can find a short overview of the settings in the configuration
here. All the settings can also be adjusted in the settings menu (use
the breadcrumbs).
For the setting...
Language [7.1]
Time/date [7.2]
Hours
Minutes
Year
Month
Day
System
Indoor unit type (read only)
Backup heater type [9.3.1]
Domestic hot water [9.2.1]
Emergency [9.5]
Number of zones [4.4]
Backup heater
Voltage [9.3.2]
Configuration [9.3.3]
Capacity step 1 [9.3.4]
Additional capacity step 2
[9.3.5] (if applicable)
Main zone
Emitter type [2.7]
Control [2.9]
Setpoint mode [2.4]
Heating WD curve [2.5] (if
applicable)
Schedule [2.1]
Additional zone (only if [4.4]=1)
Emitter type [3.7]
Control (read only) [3.9]
Setpoint mode [3.4]
Heating WD curve [3.5] (if
applicable)
Schedule [3.1]
Tank
Heat up mode [5.6]
Comfort setpoint [5.2]
Eco setpoint [5.3]
Reheat setpoint [5.4]
8.3

Possible screens

8.3.1

Possible screens: Overview

The most common screens are as follows:
8 Configuration
Refer to...
"8.4.9 Installer settings" on
page 63
"8.4.5 Space heating" on
page 56
"Backup heater" on page 63
"8.4.3 Main zone" on
page 51
"8.4.4 Additional zone" on
page 55
"8.4.6 Tank" on page 58
Installer reference guide
45