Daikin ERGA08DAV3 Installer's Reference Manual page 65

Hide thumbs Also See for ERGA08DAV3:
Table of Contents

Advertisement

#
Code
[9.6.3]
[5-04]
Offset BSH setpoint: Set point
correction for domestic hot water
temperature: set point correction for the
desired domestic hot water
temperature, to be applied at low
outdoor temperature when space
heating priority is enabled. The
corrected (higher) set point will make
sure that the total heat capacity of the
water in the tank remains
approximately unchanged, by
compensating for the colder bottom
water layer of the tank (because the
heat exchanger coil is not operational)
with a warmer top layer.
Range: 0°C~20°C
Timers for simultaneous space and domestic hot water
operation request
#
Code
[9.6.4]
[8-02]
Anti-recycle timer: Minimum time
between two cycles for domestic hot
water. The actual anti-recycling time also
depends on setting [8-04].
Range: 0~10 hours
Remark: The minimum time is 0.5 hours
even when the selected value is 0.
[9.6.5]
N/A
Minimum running timer:
Do NOT change.
[9.6.6]
[8-01]
Maximum running timer for domestic
hot water operation. Domestic hot water
heating stops even when the target
domestic hot water temperature is NOT
reached. The actual maximum running
time also depends on setting [8-04].
▪ When Control=Room
This preset value is only taken into
account if there is a request for space
heating. If there is NO request for
space heating, the tank is heated until
the setpoint has been reached.
▪ When Control≠Room
This preset value is always taken into
account.
Range: 5~95 minutes
Additional timer: Additional running
[9.6.7]
[8-04]
time for the maximum running time
depending on the outdoor temperature
[4-02].
Range: 0~95 minutes
[8-02]: Anti-recycle timer
1
0
1
0
[8-01]
[8-02]
1
Heat pump domestic water heating mode (1=active, 0=not
active)
2
Hot water request for heat pump (1=request, 0=no request)
ERGA04~08DAV3(A) + EHVZ04+08S18+23DA +
EHVZ04+08S18+23DJ
Daikin Altherma 3 R F
4P495249-1B – 2019.06
Description
Description
thermostat:
thermostat:
t
t
Time
[8-04]: Additional timer at [4-02]
t
[8-01]+
[8-04]
[8-02]
[8-01]
0
[5-03]
[4-02]
T
T
Ambient (outdoor) temperature
A
t
Time
Anti-recycle timer
Maximum running time domestic hot water
Water pipe freeze prevention
Only relevant for installations with water piping outdoors. This
function tries to protect outdoor water piping from freezing.
#
Code
[9.7]
[4-04]
Water pipe freeze prevention:
▪ 0: Intermittent
▪ 1: Continuous
▪ 2: Off
Preferential kWh rate power supply
INFORMATION
The preferential kWh rate power supply contact is
connected to the same terminals (X5M/9+10) as the safety
thermostat for the additional zone. It is only possible for the
system to have EITHER preferential kWh rate power
supply OR a safety thermostat for the additional zone.
#
Code
[9.8.1]
[D-01]
Connection to a Benefit kWh power
supply or a Safety thermostat
▪ 0 No: The outdoor unit is connected to
a normal power supply.
▪ 1 Open: The outdoor unit is connected
to a preferential kWh rate power
supply. When the preferential kWh
rate signal is sent by the electricity
company, the contact will open and
the unit will go in forced off mode.
When the signal is released again, the
voltage-free contact will close and the
unit will restart operation. Therefore,
always
function.
▪ 2
connected to a preferential kWh rate
power supply. When the preferential
kWh rate signal is sent by the
electricity company, the contact will
close and the unit will go in forced off
mode. When the signal is released
again, the voltage-free contact will
open
operation. Therefore, always enable
the auto restart function.
▪ 3 Safety
thermostat is connected to the system
(normal closed contact)
8 Configuration
A
Description
Description
enable
the
auto
restart
Closed:
The
outdoor
unit
and
the
unit
will
restart
thermostat: A safety
Installer reference guide