Sub-Camera System

Use an HDC-P1, etc. as the sub camera, which can be
controlled via the AUX REMOTE connector of the HDCU2000.
Connection example
Main camera (HDC2000)
OUTPUT
PROMPTER
REMOTE
1
2
NETWORK
TRUNK
SDI 1
SDI 2
SDI MONI
TEST OUT
SDI 2
TEST
OUT
BNC cable (HD-SDI)
Sub camera (HDC-P1, etc.)
DC power
1) A dedicated power source is required for the sub camera.
No power is supplied from the camera control unit.
2) Adjust the phase of the sub camera signal output on the
sub camera.
If NETWORK TRUNK in <PROMPT/TRUNK 2> of the
CCU CONFIGURATION menu is set to the NETWORK +
VIDEO mode, the phase of the sub camera signal output
is locked.
Settings
Main camera
MAINTENANCE menu, <TEST OUT> page:
Set OUTPUT to HD-SYNC or SD-SYNC.
<SDI OUT> page: Set SDI-2 OUT/IN to HD TRUNK/RET
IN.
Sub camera
Enable the genlock function.
(When NETWORK TRUNK in <PROMPT/TRUNK 2> of the
CCU CONFIGURATION menu is set to the NETWORK +
VIDEO mode, you do not need to enable the genlock signal
connection and genlock function.)
CCU
CRANE TRACKER
RET
DC
CONTROL
OUT
REMOTE
SDI-1/SDI-2
GENLOCK
REMOTE
1)
Note
AES/EBU signal cannot be used between the camera and
camera control unit.
Optical fiber cable (High Bit Rate)
Sub camera signal output
HD TRUNK OUT
RCP/CNU
HDCU2000
CCA cable
CNU-700
Camera Network Unit
MSU-1000/1500
Master Setup Unit
RCP-1000-series
Remote Control Panel
(for main camera)
Note
To use the tally function of the sub camera, supply the tally
signal directly to the sub camera.
Camera control unit
Format: Set it to a Single Link format.
CCU CONFIGURATION menu, <PROMPT/TRUNK 1> page:
Set AUX REMOTE to ENABLE.
24
2)
CAMERA
AUX REMOTE
CCA cable
RCP-1000-series
Remote Control Panel
(for sub camera)