Control Unit Rcu-024/025/026 - Furuno FAR-3320-NXT Instruction Manual

Hide thumbs Also See for FAR-3320-NXT:
Table of Contents

Advertisement

1. INITIAL SETTING AND ADJUSTMENT
2. Connect the PC to the LAN1 or LAN2 port of the processor unit with a LAN cable.
Note: It is possible to connect to the LAN1 or LAN2 port via a LAN hub. However,
to operate from the [Basic Setting] menu, turn off all units except the unit to be set.
Enter settings to processor units one by one.
3. Activate the web browser on the PC.
4. Enter the IP address on the address bar on the browser referring to the table
shown below.
For the initial
setting
For re-setting
the unit
When entering the IP address on the address bar, you are asked to enter ID and
password.
5. Enter the ID and password correctly then select [Login]. The [Common Installation
Setting] menu appears.
1.1.2

Control Unit RCU-024/025/026

1. Click [
below appears.
2. Click [OK] to show the [Settings] menu.
3. Click [SERVICE MODE] on the status bar, and then select [Service Login].
A dialog box for entry of password appears.
4. Enter the password and click [OK]. [Service Mode] is shown at the bottom left po-
sition of the [Settings] window.
For RCU-024: Use the keyboard on the control unit to enter the password.
For RCU-025/026: Use the software keyboard on the display to enter the pass-
word.
1-2
Access point
Gateway Network
Sensor Network
Gateway
Network
] on the status bar then select [Settings]. The pop-up message shown
IP address
192.168.31.31
172.31.16.21
Enter the IP address of the gateway or sen-
sor network according to the Equipment ID
used in the system. See the Equipment ID
list at the back of this manual.