1. INITIAL SETTING AND ADJUSTMENT
4. Set the appropriate antenna position from the [Antenna Position] pull-down list.
The interswitch function requires correct input of the antenna position.
5. Click the [OK] button.
6. To save the configuration, perform a consistency check, then save the configura-
tion data on the [Save and Sync] menu.
7. For FCR-29 or FAR-27 series antenna unit, perform the self test to confirm
that the SPU program version and DIP switch setting are as shown below.
For FCR-29 series
Open the [System Monitor] menu (see section 1.12), then click the [Self-test] but-
ton[Radar Sensor (FCR-29)][Sensor Status].
[SPU Software Version]: 0359204-03.50, or after
[SPU DIP switch (SW16-SW1)]: 0100
For FAR-27 series
Perform the self test, referring the operator's manual of FAR-27 series radar.
[SPU PROGRAM NO.]: 0359204-03.50, or after
[DIP SW]: 1000 or 1001
1.4.6

Monitoring of HUB

To monitor the HUB, do as follows.
1. Click [HUB] on the menu bar.
2. Set the items referring to the table shown below.
[Status polling interval (1 ~ 300 sec)] Polling interval for the HUB connection sta-
[Status polling timeout (1000 ~
10000 ms)]
[Status polling retries (1 ~ 10 times)] Retry times to request the HUB connection
[Threshold to alert (1 ~ 10 times)]
3. Check the checkbox for the HUB(s) to activate.
1-28
Select the appropriate
position.
Item
Remarks
tus request.
Time to wait for the HUB connection status
response.
status.
The number of times the HUB link is lost to
wait before generating an alert.