Self-Diagnostic "Stb" System Troubleshooting - Genie GPS-IC Owner's Manual

Automatic chain drive/belt drive garage door operator system
Hide thumbs Also See for GPS-IC:
Table of Contents

Advertisement

CAUTION
Staples which are too tight can cut or pinch wires.
Cut or pinched wires can cause the STB System
to stop working. When using the insulated
staples, make sure you fasten them only as tightly
as needed to hold the wire snugly.
• Make wire attachments at STB's.
– Splitting and stripping wire ends to be
connected as shown (Fig. 3-6).
– Loosen terminal screws.
– Insert wire under flat plate and tighten screw. It
does not matter which wire, white or striped,
goes on which terminal (Fig. 3-7).
• Make wire attachments at power head.
– For ProMax. STB's are connected to terminals
#2 and #3 on power head (Fig. 3-8).
– For Stealth. STB's are connected to
terminals #3 and #4 on power head (Fig. 3-8).
4. Check the following.
• Insure that no part of door or its hardware is in
path between lenses of source and sensor.
• Insure that tops of lenses are between 5"-6"
above the floor (Fig. 3-9). The brackets are
flexible and can be adjusted slightly if needed.
NOTE: STB alignment check must be performed
following connection to electrical power (see page 21).
DO NOT PLUG IN YET!
Safe-T-Beam
®
Alignment Check
After turning the electrical power on, if the
STB's are not in proper alignment, the red
LED (Source) will blink continuously.
To correct the problem – the brackets are
flexible and can be adjusted slightly to bring
the system into alignment.
When the STB's are in alignment the red LED
will stop blinking and stay on.
STB
SELF-DIAGNOSTIC TROUBLESHOOTING
SOURCE ( RED LED ) SENSOR ( GREEN LED ) INDICATED CONDITION
ON
ON
OFF
OFF
ON
OFF
2 BLINKS, PAUSE (REPEAT)
ON
2 BLINKS, PAUSE (REPEAT)
OFF
3 BLINKS, PAUSE (REPEAT)
ON
4 BLINKS, PAUSE (REPEAT)
ON
NOTE: IF OPERATING PROBLEM EXISTS, THE DOOR CAN BE CLOSED IF YOU: 1. DISCONNECT THE STB SYSTEM FROM THE OPERATOR AND 2. HOLD WALL CONTROL BUTTON
DOWN UNTIL DOOR IS CLOSED. ( REMOTE CONTROL & WIRELESS KEYPAD WILL NOT WORK WITHOUT STB )
CUSTOMER SERVICE: 1.800.354.3643 or www.geniecompany.com
FIG. 3-6
Splitting and
stripping.
3
4
FIG. 3-8 (Stealth)
Attachments at
power head.
NORMAL OPERATION
1. POWER HEAD NOT POWERED
2. WIRING FROM POWER HEAD BAD
1. WIRING TO SOURCE MISSING OR BAD
2. POWER HAS BEEN INTERRUPTED
1. BEAM NOT ALIGNED 2. BEAM OBSTRUCTED
3. SENSOR DEFECTIVE
1. WIRE TO SENSOR MISSING OR BAD
2. SENSOR DEFECTIVE
1. SENSOR RECEIVING INTERFERENCE
1. SOURCE NOT SENDING PULSES
2. SOURCE DEFECTIVE
FIG. 3-8 (ProMax)
FIG. 3-7
Attachments
Attachments at
at STB.
power head.
top edge of lens between
5" - 6" above floor.
FIG. 3-9 Check lens height.
REQUIRED ACTION
NONE REQUIRED
1. CHECK BREAKERS, FUSES, PLUGS
2. CHECK WIRING FOR OBVIOUS SHORTS
1. CHECK WIRING
2. REMOVE POWER AND REAPPLY
1. CHECK ALIGNMENT 2. CHECK FOR OBSTRUCTION
3. CALL CUSTOMER SERVICE
1. CHECK WIRING
2. CALL CUSTOMER SERVICE
1. ATTEMPT TO DETERMINE SOURCE OF INTERFERENCE
2. CALL CUSTOMER SERVICE
1. CALL CUSTOMER SERVICE
2. CALL CUSTOMER SERVICE
2
3
19

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pmx-ic bStealthPmx-ic b series

Table of Contents