Principal Wiring Connections - Frymaster Enodis BIPH52 Series Service Manual

Hide thumbs Also See for Enodis BIPH52 Series:
Table of Contents

Advertisement

1.10

Principal Wiring Connections

FROM TRANSFORMER BOX
FROM TRANSFORMER BOX
LEFT VAT
FROM
PROBE
PROBE
K3
C1 PIN 4 (24VAC)
V2D
K3
GROUND
MODULE VALVE 1
J1 PIN 8 VIA K1
OPTIONAL DRAIN SWITCH
FROM T1, JUMPERED TO PIN 8
GROUND, JUMPERED TO PIN 11
JUMPERED TO PIN 9 AND T2
JUMPERED FROM PIN 4
JUMPERED FROM PIN 5
JUMPERED FROM PIN 1
GROUND, JUMPERED FROM PIN 2
FROM T2, JUMPERED TO PINS 3 & 9
C1
LINE VOLTAGE (L1)
1
GROUND
2
LINE VOLTAGE (COM)
3
24VAC
4
12VAC
5
6
12VAC
HOOD RELAY
7
LINE VOLTAGE (L1)
8
LINE VOLTAGE (COM)
9
1
HEAT STRIP
2
BLK
3
4
5
WHT
6
7
BLK
8
GRN
9
BLK
252 and 452's ONLY, On 352 & 552's Heat
strip is attached to pins 7 & 9 of Line
Connector C3
J1
TO
FROM
1
J3 PIN 1
2
J2 PIN 14
GROUND
3
J3 PIN 3
4
COMPUTER
5
COMPUTER
6
J2 PIN 15
COMPUTER
7
C2 PIN 13 (BL DOWN)
COMPUTER
8
NOT USED
9
GAS VALVE
COMPUTER
10
C2 PIN 10 (BL UP)
ALR (RIGHT)
11
COMPUTER
12
AD (LEFT)
J3 PIN 6
GND
GROUND
J1 PIN 2 & J3 PIN 2
V2D
J1 PIN 9
J1 PIN 6
PWR
MODULE 25V
AD
J2 PIN 12
AS
V2S
C2
1
2
3
4
JUMPERED TO PIN 6
HEAT STRIP
ON 352 0R 552
JUMPERED TO PIN 7
5
6
7
8
JUMPERED FROM PIN 3
9
10
FROM J1 PIN 10
11
12
FROM J1 PIN 7
13
14
FROM J3 PIN 10
15
FROM J3 PIN 7
AIR
N.C.
PRESSURE
SWITCH
N.O.
(CE AND SOME
EXPORT UNITS)
COM
BLACK
GREEN
WHITE
RED
ORANGE
BLUE
WHITE/BLACK
DRAIN SOLENOID
FILTER PUMP
C1 PIN 1
C1 PIN 3
(IN COMPONENT BOX)
FILTER PUMP
SOLENOID
J2
TO
1
C1 PIN 6 (12VAC)
COMPUTER (12VAC)
2
GROUND
3
C1 PIN 5 (12VAC)
COMPUTER (12VAC)
4
RT HEAT RELAY (K2)
5
RELAYS (12VDC) & J3 PIN 5
LT HEAT RELAY (K1)
6
7
K5
C1 PIN 4 (24VAC)
8
9
K3
V1S OR V1D
10
RIGHT ALARM OUT (FULL VAT)
C1 PIN 1 (L1)
11
SOUND DEVICE
12
LEFT ALARM OUT (DUAL VAT)
13
COMPUTER
14
COMPUTER
MODULE VALVE 1 (DUAL VAT)
15
COMPUTER
J3 PIN 8 VIA K2
OPTIONAL DRAIN SWITCH
MODULE VALVE 1 (FULL VAT)
C3
1
LINE VOLTAGE L1
2
GROUND
3
LINE VOLTAGE COM
4
OIL RETURN SWITCH
5
6
7
8
9
RED
WHITE & BLACK
TO OIL RETURN SWITCHES OF ADJACENT FRYERS
BLUE
ORANGE
TO OIL RETURN SWITCHES OF ADJACENT FRYERS
C5
C1 PIN 3
1
BLOWER
J3 PIN 12
2
1-37
TO T1 & J3 PIN 11
TO GROUND
TO T2 & C5 PIN 1
TO J1 PIN 8 & J3 PIN 8
TO J3 PIN 3
TO J3 PIN 1
TO J3 PIN 5 (12VDC)
T1
C2 PIN 1
C2 PIN 3, C2 PIN 12
T2
RIGHT OR FULL VAT
J3
FROM
TO
1
J2 PIN 1
PROBE
2
J2 PIN 14
3
J2 PIN 3
4
J2 PIN 5
5
C1 PIN 7
J2 PIN 13
PROBE
6
C2 PIN 15 (BL DOWN)
K5
7
PWR VIA K2
8
9
GAS VALVE
K5
10
C2 PIN 14 (BL UP)
11
BLOWER VIA K4
12
K4
C5 PIN 2
GROUND
GND
GROUND
V1D
J3 PIN 9
PWR
MODULE 25V
ALR
J2 PIN 10
V1S
J3 PIN 9
TO FILTER BOX

Advertisement

Table of Contents
loading

Table of Contents