3. Remove the sheet metal screws securing the ignitor to the mounting plate and pull the ignitor
from the fryer.
4. Reverse the procedure to install the replacement ignitor.

1.6.6 Replacing or Cleaning a Combustion Air Blower

1. Disconnect the blower wiring harness, remove the blower assembly mounting nuts, and remove
the blower assembly from the fryer. If cleaning the motor, continue with Step 2; otherwise,
install the replacement blower, reconnect the wiring harness, and then go to Step 6.
2. Remove the blower motor shield and separate the blower motor from the housing as shown in
the illustration on the following page.
Wiring connection
Blower assembly
mounting nuts
1-11
Flame Sensor Wire
Gas Enrichment Tube
Ignition Cable