Replacing The Frypot - Frymaster Enodis BIPH52 Series Service Manual

Hide thumbs Also See for Enodis BIPH52 Series:
Table of Contents

Advertisement

DO NOT attempt to drain more than one full frypot or two split frypots into the SDU
3. Position a container beneath the oil return fitting at the front of the cabinet. Disconnect the
flexible oil line from the fitting, allowing any residual oil to drain into the container.
4. At the rear of the fryer, unplug the left connector (as viewed from the rear of the fryer) from the
transformer box. Using a pin pusher, push the pump solenoid valve wires from Pins 7 and 9.
5. Remove the four nuts and bolts attaching the motor mount to the rear motor mount support.
6. At the front of the fryer, remove the cover plate from the front of the motor and disconnect the
motor wires.
7. Place a 1-foot (30.5-cm) length of wood (or similar support) beneath the motor mount near the
front of the unit and remove the two remaining nuts and bolts attaching the motor mount to the
front cabinet cross-brace.
8. Carefully remove the support and lower the motor mount to the floor, allowing the rear of the
mount to slide forward and off the rear motor mount support.
9. Disconnect the return flexline from the pump. The motor and pump assembly can now be pulled
from beneath the fryer and the failed component can be removed and replaced.
10. Position the new/repaired motor and pump assembly beneath the fryer and reconnect the oil
return flexline to the pump. Lift the rear of the motor mount up and onto the rear motor mount
support.
11. Lift the front of the motor mount up and support it with a 1-foot (30.5-cm) piece of wood or a
similar support. Install but do not tighten the two nuts and bolts that attach the motor mount to
the front cabinet cross-brace.
12. Install and tighten the four nuts and bolts that secure the motor mount to the rear motor mount
support. Reconnect the solenoid valve wires to Pins 7 and 9 of the 9-pin connector (polarity
does not matter) and reconnect the plug.
13. At the front of the fryer, tighten the two nuts and bolts at the front of the motor mount.
Reconnect the motor power wires and reinstall the wiring cover plate.
14. Reconnect the oil return flexline and reinstall the filter pan.
15. Reconnect the unit to the electrical power supply, fill the frypots with oil and check for proper
operation.
1.6.10

Replacing the Frypot

1. Disconnect the fryer from the electrical and gas supplies.
DANGER
at one time.
1-17

Advertisement

Table of Contents
loading

Table of Contents