System Operation and Functions
2.
The muting sensor is blocked and the safety function of the F3SG-RA is disabled
When muting sensors A1 and B1 are turned ON in this order, and the muting state is enabled. In this
state, the safety function of F3SG-RA is disabled.
3.
Muting sensor A1 is turned OFF
The workpiece has completely passed the muting sensor A1 and the sensor starts turning OFF. For
standard muting system, muting is released here. For exit-only muting, F3SG-RA's safety function is
disabled for the exit-only muting delay time: T5.
4.
Muting sensor B1 is turned OFF
The workpiece has completely passed the muting sensor B1 and the sensor is turned OFF. F3SG-RA
disables its safety function if it is within the exit-only muting delay time.
F3SG-R
62
User's Manual
Hazardous zone
A1 B1
Workpiece
Hazardous zone
A1 : Muting sensor to be connected
to muting input A
B1 : Muting sensor to be connected
to muting input B
Hazardous zone
A1 : Muting sensor to be connected
to muting input A
B1 : Muting sensor to be connected
to muting input B
F3SG-RA
A1 : Muting sensor to be connected
to muting input A
V
B1 : Muting sensor to be connected
to muting input B
d1
d2
A1 B1
F3SG-RA
Workpiece
V
d1
d2
A1 B1
F3SG-RA
V
Workpiece
d1
d2