Omron F3SG-2RE0430P30 User Manual page 205

Safety light curtain
Table of Contents

Advertisement

 Emitter Adapter Cable (C) (F39-JGR3M-C48-L, sold separately)
44.7
M12 IP67 connector, 8-wire
<Internal Wiring>
Connected to connector of F3SJ-A/B
emitter cable
F3SJ Series
(Interlock selection input / Muting input 1)
+24 VDC
(Test input)
(Reset input)
(Communication line (+))
(Communication line (-))
0 VDC
(F3SJ-A: Auxiliary output 2/ Muting input 2)
(F3SJ-B:Not used/Muting input 2)
(Shield)
 Receiver Adapter Cable (C) (F39-JGR3M-C48-D, sold separately)
44.7
M12 IP67 connector, 8-wire
<Internal Wiring>
Connected to connector of F3SJ-A/B
receiver cable
F3SJ Series
Safety output 2
+24 VDC
Safety output 1
(Auxiliary output 1)
(Communication line (+))
(Communication line (-))
0 VDC
(External device monitoring input)
(Shield)
300
Insulated vinyl round cable dia. 6-mm
1
2
7
3
8
4
6
5
Emitter Adapter Cable (C)
Male
-
1
1
Brown
2
2
-
3
3
-
4
4
-
5
5
-
6
6
Blue
7
7
-
8
8
300
Insulated vinyl round cable dia. 6-mm
1
2
7
3
8
4
6
5
Receiver Adapter Cable (C)
Male
White
1
1
Brown
2
2
Black
3
3
-
4
4
-
5
5
-
6
6
Blue
7
7
-
8
8
Wiring/Installation
(Unit: mm)
40.7
M12 IP67 connector, 5-wire
1
2
5
Connected to Power Cable or
4
3
Double-Ended Cable of F3SG-RE emitter
F3SG-RE
Female
1
1
Brown
+24 VDC
(Operating Range Select Input)
2
2
-
0 VDC
3
3
Blue
(Not used)
4
4
-
5
(Unit: mm)
40.7
M12 IP67 connector, 5-wire
1
2
5
Connected to Power Cable or
4
3
Double-Ended Cable of F3SG-RE receiver
Female
F3SG-RE
1
Brown
1
2
White
2
3
Blue
3
4
Black
4
5
+24 VDC
OSSD 2
0 VDC
OSSD 1
E