Omron F3SG-2RE0430P30 User Manual page 114

Safety light curtain
Table of Contents

Advertisement

System Operation and Functions
You can specify beams you want to configure for warning zone. (Fig. 4& 5)
Configuration cannot be executed for cases shown below.
• All beams are configured as a warning zone (Fig. 7).
• A warning zone is specified without including any of end beams (Fig. 8)
When it is configured for the F3SG-RA in cascade connection to have the detection zone, it is possible
for the other F3SG-RA's to have the warning zone for the all beams. (Fig. 6)
For the application as shown in Fig. 6, make sure the primary sensor has the detection zone and the secondary sensor
has the warning zone.
Operation Example:
Safety output ON
Warning zone output OFF
Fig. 1
Beam state
(Warning zone only)
Beam state
(Detection zone)
Auxiliary output
(warning zone)
F3SG-R
90
User's Manual
Detection Zone
Warning Zone
Unblocked
Blocked
Unblocked
Blocked
ON
OFF
ON
OSSD
OFF
Safety output ON
Warning zone output ON
Fig. 2
Safety output OFF
Warning zone output OFF
Fig. 3