Omron F3SG-2RE0430P30 User Manual page 37

Safety light curtain
Table of Contents

Advertisement

ON
Voltage
Input Voltage
OFF
Voltage
* The Vs indicates a supply voltage value in your environment.
Overvoltage Category (IEC
60664-1)
Indicators
Protective Circuit
Insulation Resistance
Dielectric Strength
Functional
Mutual Interference Prevention
(Scan Code)
Cascade Connection
Test Function
Safety-Related Functions
Environmental
Ambient
Operating
Temperature
Storage
Ambient
Operating
Humidity
Storage
Ambient Illuminance
Degree of Protection
(IEC 60529)
Vibration Resistance
(IEC 61496-1)
Shock Resistance
(IEC 61496-1)
F3SG-4RA-14
F3SG-4RA-30
F3SG-2RA-14
F3SG-2RA-30
TEST:
24 V Active: 9 V to Vs (sink current 3 mA max.) *
0 V Active: 0 to 3 V (source current 3 mA max.)
MUTE A/B:
PNP: Vs to Vs-3 V (sink current 3 mA max.) *
NPN: 0 to 3 V (source current 3 mA max.)
RESET:
PNP: Vs to Vs-3 V (sink current 5 mA max.) *
NPN: 0 to 3 V (source current 5 mA max.)
TEST:
24 V Active: 0 to 1.5 V or open
0 V Active: 9 V to Vs or open
MUTE A/B, RESET:
PNP: 0 to 1/2 Vs, or open *
NPN: 1/2 Vs to Vs, or open *
II
Refer to 1-4-1. LED Indicator Status
Output short protection, Power supply reverse polarity protection
20 M or higher (500 VDC megger)
1,000 VAC, 50/60 Hz (1 min)
This function prevents mutual interference in up to
two F3SG-RA systems.
4-1-4. Mutual Interference Prevention
Number of cascaded segments: 3 max.
Total number of beams: 255 max.
Cable length between sensors: 10 m max.
Self-test (at power-on, and during operation)
External test (light emission stop function by test
input)
Interlock
External device monitoring (EDM)
Pre-reset
Fixed blanking/Floating blanking
Reduced resolution
Muting/Override
Scan code selection
PNP/NPN selection
Response time adjustment
Chapter 2 System Operation and Functions
Chapter 3 Setting with DIP Switch
-10 to 55°C (14 to 131°F) (non-icing)
-25 to 70°C (-13 to 158°F)
35% to 85% (non-condensing)
35% to 95%
Incandescent lamp: 3,000 Ix max. on receiver surface
Sunlight: 10,000 Ix max. on receiver surface
IP65 and IP67
10 to 55 Hz, Multiple amplitude of 0.7 mm, 20 sweeps for all 3 axes
100 m/s
2
, 1000 shocks for all 3 axes
Overview and Specifications
F3SG-4RE14
F3SG-4RE30
F3SG-2RE14
F3SG-2RE30
Operating Range Select Input:
Long: 9 V to Vs (sink current 3 mA max.) *
Short: 0 to 3 V (source current 3 mA max.)
-
-
Self-test (at power-on, and during operation)
-
E
F3SG-R
13
User's Manual

Advertisement

Table of Contents
loading

Table of Contents