RF RECEIVER & SUPERVIS ORY T IMER OPTI ONS (ADDRESS 2029-2044 & 2056)
ADDRESS 2056
Number of RF
LEFT DIGIT
Receivers
blank (•)
Default for Number of Receivers
depends on Easy Menu Question for
RF Transmitters.
RF SUPERVISORY TIMERS: RF Supervisory Timers may be programmed for each type of trans-
mitter used. A transmitter will send a transmission every time it is tripped, when there is NO activity,
the transmitter sends a status transmission about once an hour. If the receiver does NOT receive
ANY signal (a trip or a status) from a transmitter in the time specified for transmitter type, a system
trouble "
WIRELESS TROUBLE/E04-NN SERVICE
1. Select timer delay from the table shown. Timers are programmed in increments of 30 minutes
each. Valid entries are [3] through [F] (90 minutes-450 minutes).
2. Enter in corresponding address locations below (right nibble).
u
3. Press
to save.
RF SUPERVISORY
RF TRANSMITTER
TIMER
Type 0
Window/Door, 2 Pt.
Type 1
Window/Door, 2 Pt.
Type 2
Window/Door, 2 Pt.
Type 3
Window/Door, 2 Pt.
Type 4
RESERVED
Type 5
Type 6
Type 7
Smoke Detector
Type 8
Smoke Detector
Type 9
RESERVED
Type A
Dual Tech.
Type B
RESERVED
Type C
Window/Door, 4 Pt.
Type D
Type E
Smoke Detector
Type F
Napco Glass Break
NOTE: These timers apply only to Supervised RF Transmitters (see RF Transmitters in Easy Menu Driven Mode Programming).
LIBRA LIB-P432EX Series Programming Instructions
DATA ENTRIES
RIGHT DIGIT
blank (•)
1
2
" will be displayed at the keypad.
RF SUPERVISORY DELAY
ADDR
TIME (Select timer delay
from the table at right)
2029
2030
2031
2032
PIR
2034
PIR
2035
2036
2037
2039
2041
PIR
2042
2043
2044
[Default = blank (•) from address 2029-2044]. Default = 8 (240 minutes)
RF RECEIVERS: Up to 2 RF Receivers may be pro-
RF RECEIVER(S)
grammed.
1. Select the number of receivers from the table
None
shown.
1
2
2. Enter number in address location shown.
3. Press
RF SUPERVISORY TIMERS
DATA ENTRIES
B
C
D
E
F
u
to save.
DELAY
3
90 min.
4
120 min.
5
150 min.
6
180 min.
7
210 min.
8
240 min.
9
270 min.
0
300 min.
330 min.
360 min.
390 min.
420 min.
450 min.