Page 6
GEM-RP1CAe2/GEM-K1CA Keypad Easy Program Menu
o create a custom program using the GEM-RP1CAe2/GEM-K1CA keypad, simply answer the following questions and record
T
your information on the Easy Menu Programming Worksheet. In each of the following steps, press
NEXT/YES button to go forwards, the PRIOR/NO button to go backwards,
# o f Z n s i n A r e a 1
E n t e r # Z o n e s X X
(Direct Entry)
E Z Z o n e D o u b l i n g
E n a b l e d ?
Y / N
(Press YES or NO)
F i r e
Z o n e s
E n t e r Z o n e # ° °
(Direct Entry)
2 - W i r e F i r e Z n s
En ter Zone #
° °
(Direct Entry)
R e p o r t A l l Z o n e s
T o C e n t r a l ? Y / N
(Press YES or NO)
E x i t / E n t r y Z o n e s
E n t e r Z o n e #
(Direct Entry)
I n t e r i o r Z o n e s
E n t e r Z o n e #
(Direct Entry)
2 4 H o u r Z o n e s
E n t e r Z o n e #
(Direct Entry)
X
GEM-P1664EX Programming Instructions
Total Number of Zones in Area 1 (New Program Only)
•
Enter the total number of zones to be programmed for Area 1.
•
Valid entries are from 01 to 64. Directly enter the total number of zones, including leading zeros.
•
The system is based on groups of 4 zones each (after the first 8 zones), and will automatically
round up to the next group of 4. For example, if you enter 18, it will automatically convert this to
U
20 zones. Press
to save. Press the NEXT/YES button to proceed.
Panel Zone Doubling (New Program Only)
•
To double the number of hardwired panel zones from 8 to 16, press YES.
•
If Panel Zone doubling is not desired, press the PRIOR/NO button.
•
The 16 zones will remain EOL terminated zones, requiring Normally Closed devices only.
•
Refer to Wiring Diagram and Installation Instructions for wiring instructions
Fire Zones in Area 1 (New Program Only)
•
Enter the zone number of any Fire Zones (including 2-wire, 4-wire or wireless).
•
Valid entries are from 01 to 64.
•
Directly enter each zone number, including leading zeros, and press
peat for any additional zone(s). Press the NEXT/YES button to proceed.
2-Wire Fire Zones in Area 1
•
Enter the zone number of any Fire Zone (from previous question) to be used with 2-wire
smoke detectors.
•
Valid entries are 07 and 08. Directly enter each zone number, including leading zeros.
U
•
Press
to save, and repeat for any additional zone(s); press NEXT/YES to proceed.
NOTE: Only zones which have been designated as Fire Zones can be programmed as 2 Wire
Fire zones. JP3 must be set to "2-WF" position for 2-wire fire. (refer to Installation Instructions).
Local or Central Station Reporting System (New Program Only)
Press the NEXT/YES button for all zones to report; press the PRIOR/NO button for local system
Exit/Entry Zones in Area 1 (New Program Only)
•
Enter the zone numbers of zones to be used as Exit/Entry zones.
X X
•
Valid entries are from 01 to 64. Directly enter each zone number, including leading zeros.
U
•
Press
to save and repeat for any additional zone(s); press the NEXT/YES button to proceed.
NOTE: Exit/Entry Entry time of 30 seconds will automatically be programmed.
Interior Zones in Area 1 (New Program Only)
•
Enter the zone numbers to be used as Interior Zones.
X X
•
Valid entries are from 01 to 64. Directly enter each zone number, including leading zeros.
U
•
Press
to save and then repeat for any additional zone(s).
•
Press the NEXT/YES button to proceed.
•
All Interior zones will also be automatically programmed as "Exit/Entry Follower" and as
"Power Up Delay" zones.
24 Hour Zones in Area 1 (New Program Only)
•
Enter the zone numbers of zones to be used as 24 Hour zones.
° °
•
Valid entries are from 01 to 64. Directly enter each zone number, including leading zeros.
U
•
Press
to save and repeat for any additional zone(s); press the NEXT/YES button to proceed.
NOTE: 24 Hour Zones will automatically be programmed as audible (Burg Output).
U
D
to save and
or
(New Program Only)
L
WI1386 5/05
to set cursor, the
R
twice to exit at any time.
C
U
to save, and then re-
NAPCO Security Systems