Easy Menu Driven Program Mode; Dealer Program - Preliminary Information; Accessing Dealer Program Mode; Customizing A Default Program - NAPCO LIBRA-P432EX Series Programming Instructions Manual

Control panel/communicator
Table of Contents

Advertisement

EASY MENU DRIVEN PROGRAM MODE

DEALER PROGRAM - PRELIMINARY INFORMATION

The Default Dealer Code is
gram a custom Dealer Code, which replaces the Default Dealer Code. If you clear your Dealer Code, use the Default Dealer
Code once again to enter programming.
After entering codes or data, press the save
If the keypad is in the Program Mode and no activity is detected for longer than 4 minutes, a steady tone will sound.
Silence the sounder by the
A panel that has been COLD STARTED (Address Location 2286) performs identically to a new panel.
When programming a Multiple Area System, Direct Address Programming Mode must be used to complete the program.
For ease of programming, it is recommended that a GEM-DXRP1 or GEM-DXK1 be used. For Programming Instruc-
tions with the GEM-DXRP2 / GEM-DXK2, GEM-DXRP3 / GEM-DXK3 and the GEM-DXK4RF series, see WI1771.

ACCESSING DEALER PROGRAM MODE

1. Press
456789 w
2. Press PRIOR ("
3. Press NEXT ("r" or
4. Press
yy

CUSTOMIZING A DEFAULT PROGRAM

For new panels, you can design a default program that will best suit your application. Using this procedure, you will configure the panel for:
Number of Zones in Area 1
Panel Zone Doubling
Fire Zones in Area 1
2-Wire Fire Zones in Area 1
Local or Central Station Reporting System
Exit/Entry Zones in Area 1
Interior Zones in Area 1
24 Hour Zones in Area 1
Chime Zones in Area 1
Chime 2 Zones in Area 1
Exit/Entry2 Zones in Area 1
This procedure will automatically set up system keypads, wireless transmitters, etc. After your basic default program has been
loaded, you may alter it as necessary in the Direct Address Program Mode.
NEW PANELS: The custom default program may be created for new panels only. Once the panel has been programmed by any
means, the number zones will be suppressed and cannot be changed. Should it be necessary to create a new custom default pro-
gram, (a) from the Dealer Program Mode, press the
2285 (Clear Program); (c) press the
NAPCO Security Systems
456789
u
button. Data will not be stored into memory unless
button to continue, or by pressing the
G
Dealer Code
" or
) button until "ACTIVATE PROGRAM Y/N" appears on LCD screen.
X
q
) button to Enter Dealer Program Mode.
p
to Exit Dealer Program Mode when finished.
50mS Loop Response Zones
Aux Output Activated on Alarm Zones
Sensor Watch Zones
Keypad Sounder on Alarm Zones
Auto Bypass re-entry Zones
Enable no EOLR Zones
Enable Telco Line Fault Test
Enable Burg Output Chirp on Keyfob
Enable CP-01 Programming
Number of Keypads in Area 1
Central Station Receiver 1 Tel. Number
y
u
button and start over.
. Use this code to enter the Dealer Program Mode to pro-
y
button to exit.
button to enter the Direct Address Program Mode; (b) access Location
LIBRA LIB-P432EX Series Programming Instructions
u
is pressed.
Central Station Receiver 1 Account Number
Central Station Receiver 1 Format
Enter User Codes
RF Transmitter Points
Quick "Enroll" Method
Key Fob Transmitters
Enter Zone Descriptions
Enter Date
Enter Time
Dealer Code
Test Timer
Page 5

Advertisement

Table of Contents
loading

Table of Contents