Ricoh D649 Field Service Manual page 31

Table of Contents

Advertisement

Code
Meaning
The other end sent RTN or PIN
after receiving a page,
0-08
because there were too many
errors
Non-standard post message
0-14
response code received
The other terminal is not
0-15
capable of specific functions.
Suggested Cause/Action
• Check the line connection.
• Replace the FCU.
• The other end may have jammed, or run out of
paper or memory space.
• Try adjusting the tx level and/or cable equalizer
settings.
• The other end may have a defective modem/FCU;
try sending to another machine.
• Check for line problems and noise.
Cross reference
• Tx level - NCU Parameter 01 (PSTN)
• Cable equalizer - G3 Switch 07 (PSTN)
• Dedicated Tx parameters in Service Program Mode
• Incompatible or defective remote terminal; try
sending to another machine.
• Noisy line: resend.
• Try adjusting the tx level and/or cable equalizer
settings.
• Replace the FCU.
Cross reference
See error code 0-08.
The other terminal is not capable of accepting the
following functions, or the other terminal's memory is full.
• Confidential rx
• Transfer function
• SEP/SUB/PWD/SID
Error Codes
29

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Aficio mp c305spfAficio mp c305sp

Table of Contents